Installation, Operating and Maintenance Instruction Model L, LN
Page 48
Sound pressure level L
pA
measured in 1 m distance
from pump surface acc. to DIN 45635, part 1 and 24.
Room and foundation influences are not considered.
The tolerance for these values is 3 dB(A).
Addition with 60 Hz-operation:
Pump alone:
Pump with motor: +4 dB(A)
3.6 Permitted Nozzle Loads and Torques
at the Pump Nozzles ...
... following the Europump-Recommendation for
pump acc. to ISO 5199.
The data for forces and torques are only valid for static
piping loads and for the pump unit with grouted
standard baseplate.
All values for forces and torques refer to standard
materials EN-GJL-200 (Model LN) and EN-GJL-250
(Model L).
Sizes
Suction nozzle Discharge nozzle
DN
Forces in N Torques in Nm
DN
Forces in N Torques in Nm
Fx Fy Fz
F
Mx My Mz
M
Fx Fy Fz
F
Mx My Mz
M
LN 32-125 50 578 525 473 910 490 350 403 718 32 315 298 368 578 385 263 298 560
LN 32-160 50 578 525 473 910 490 350 403 718 32 315 298 368 578 385 263 298 560
LN 32-200 50 578 525 473 910 490 350 403 718 32 315 298 368 578 385 263 298 560
LN 40-125 65 735 648 595 1155 525 385 420 770 40 385 350 438 683 455 315 368 665
LN 40-160 65 735 648 595 1155 525 385 420 770 40 385 350 438 683 455 315 368 665
LN 40-200 65 735 648 595 1155 525 385 420 770 40 385 350 438 683 455 315 368 665
LN 40-250 65 735 648 595 1155 525 385 420 770 40 385 350 438 683 455 315 368 665
LN 50-125 65 735 648 595 1155 525 385 420 770 50 525 473 578 910 490 350 403 718
LN 50-160 65 735 648 595 1155 525 385 420 770 50 525 473 578 910 490 350 403 718
LN 50-200 65 735 648 595 1155 525 385 420 770 50 525 473 578 910 490 350 403 718
LN 50-250 65 735 648 595 1155 525 385 420 770 50 525 473 578 910 490 350 403 718
LN 65-125 80 875 788 718 1383 560 403 455 823 65 648 595 735 1155 525 385 420 770
LN 65-160 80 875 788 718 1383 560 403 455 823 65 648 595 735 1155 525 385 420 770
LN 65-200 80 875 788 718 1383 560 403 455 823 65 648 595 735 1155 525 385 420 770
LN 65-250 80 875 788 718 1383 560 403 455 823 65 648 595 735 1155 525 385 420 770
L 65-315 80 875 788 718 1383 560 403 455 823 65 648 595 735 1155 525 385 420 770
LN 80-160 100 1173 1050 945 1838 613 438 508 910 80 788 718 875 1383 560 403 455 823
LN 80-200 100 1173 1050 945 1838 613 438 508 910 80 788 718 875 1383 560 403 455 823
LN 80-250 100 1173 1050 945 1838 613 438 508 910 80 788 718 875 1383 560 403 455 823
L 80-315 100 1173 1050 945 1838 613 438 508 910 80 788 718 875 1383 560 403 455 823
L 80-400 100 1173 1050 945 1838 613 438 508 910 80 788 718 875 1383 560 403 455 823
L 100-160 125 1383 1243 1120 2170 735 525 665 1068 100 1050 945 1173 1838 613 438 508 910
L 100-200 125 1383 1243 1120 2170 735 525 665 1068 100 1050 945 1173 1838 613 438 508 910
L 100-250 125 1383 1243 1120 2170 735 525 665 1068 100 1050 945 1173 1838 613 438 508 910
L 100-315 125 1383 1243 1120 2170 735 525 665 1068 100 1050 945 1173 1838 613 438 508 910
L 100-400 125 1383 1243 1120 2170 735 525 665 1068 100 1050 945 1173 1838 613 438 508 910
L 125-200 150 1750 1575 1418 2748 875 613 718 1278 125 1243 1120 1383 2170 735 525 665 1068
L 125-250 150 1750 1575 1418 2748 875 613 718 1278 125 1243 1120 1383 2170 735 525 665 1068
L 125-270 150 1750 1575 1418 2748 875 613 718 1278 125 1243 1120 1383 2170 735 525 665 1068
L 125-315 150 1750 1575 1418 2748 875 613 718 1278 125 1243 1120 1383 2170 735 525 665 1068
L 125-400 150 1750 1575 1418 2748 875 613 718 1278 125 1243 1120 1383 2170 735 525 665 1068
L 150-250 200 2345 2100 1890 3658 1138 805 928 1680 150 1575 1418 1750 2748 875 613 718 1278
L 150-315 200 2345 2100 1890 3658 1138 805 928 1680 150 1575 1418 1750 2748 875 613 718 1278
L 150-400 200 2345 2100 1890 3658 1138 805 928 1680 150 1575 1418 1750 2748 875 613 718 1278
4. Transport, Handling, Storage
4.1 Transport, Handling
Check the pump / pump unit immediately upon
delivery / receipt of despatch for damage or
missing parts.
The pump / pump unit must be transported
carefully and by competent personnel. Avoid
serious impacts.
Keep the pump/pump unit in the same position in
which it was supplied from the factory. Take note
of the instructions on the packaging.
The suction and discharge side of the pump must
be closed with plugs during transport and storage.
Dispose of all packing materials in accordance
with local regulations.