Instruction Manual
4.0 Specifications
Max. Working Pressure:
oo
PVC lens, 130 psig (9 bar) @ 70 F (21 C)
oo
PVDF lens, 150 psig (10 bar) @ 70 F (21 C)
Max. Fluid Temperature:
oo
PVC lens, F/NPT connectors 130 F (54 C) @ 0 PSI
oo
PVDF lens, tubing connectors 200 F (93 C) @ 0 PSI
Full scale accuracy +/- 6%
Input Power requirement: 9 - 28 VDC
Sensor only output cable: 3-wire shielded cable, 6ft
Pulse output signal: Digital square wave (2-wire) 25ft max.
Voltage high = 5Vdc,
Voltage low < .25Vdc
50% duty cycle
Output frequency range: 4 to 500Hz
Alarm output signal: Open collector. Active low above
programmable rate set point.
30Vdc maximum, 50mA max load.
Active low < .25Vdc
Enclosure: NEMA type 4X, (IP56)
Approximate shipping wt: 1 lb. (.45 kg)
MICRO-FLOPage 4
Maximum Temperature vs. Pressure
0 30(2) 60(4) 90(6) 120(8) 150(10)
STATIC PRESSURE PSI (BAR)
oo
70 F (21 C)
oo
96 F (36 C)
oo
122 F (50 C)
oo
148 F (64 C)
oo
200 F (93 C)
TEMPERATURE
oo
174 F (79 C)
Models with
PVDF Lens and connectors
Models with
PVC Lens or connectors
4.1 Temperature and Pressure limits