Owner's manual
Table Of Contents
- 1 Overview
- 2 Safety instructions
- 3 Commissioning
- 4 Operation
- 4.1 Switching on or off the photometer
- 4.2 General operating principles
- 4.3 Photometer settings and system administration
- 4.4 Zero adjustment
- 4.5 Measuring in Concentration mode
- 4.5.1 Measuring cell tests with barcode
- 4.5.2 Measuring reagent tests with AutoSelector
- 4.5.3 Measuring reagent-free tests and user-defined methods
- 4.5.4 Exceeding the upper or lower limits of the measuring range
- 4.5.5 Selecting a method manually
- 4.5.6 Settings for Concentration mode
- 4.5.7 Measuring diluted samples
- 4.5.8 Sample blank value
- 4.5.9 Reagent blank value
- 4.5.10 Automatic Turbidity correction
- 4.5.11 Programming / modifying user-defined methods
- 4.5.12 The IQ LabLink procedure
- 4.6 Measuring the Absorbance / % Transmission
- 4.7 Multi wavelengths methods
- 4.8 Spectrum
- 4.9 Kinetics
- 4.10 Timer
- 4.11 Memory
- 4.11.1 Overview
- 4.11.2 Instructions on using USB memory devices
- 4.11.3 Measurement datasets
- 4.11.4 Saving measurement datasets manually
- 4.11.5 Saving measurement datasets automatically
- 4.11.6 Displaying measurement data memory
- 4.11.7 Filtering measurement datasets
- 4.11.8 Inverting filters
- 4.11.9 Erasing stored measurement datasets
- 4.12 Copying files
- 4.13 Transmitting data
- 4.14 Analytical quality assurance (AQA)
- 4.15 User management
- 4.16 Reset
- 4.17 Photometer information ([Info])
- 4.18 Lamp counter
- 4.19 Software and methods update
- 5 Maintenance and cleaning
- 6 What to do if ...
- 7 Technical data
- 8 Accessories and options
- Appendix

photoLab
®
6100 VIS Operation
103
ba75847e01 08/2009
For each export procedure you can select the location where the PC-
readable files (*.csv) should be stored: either the photometer (Internal DataB
folder) or an external memory (USB memory).
The files stored in the photometer (Internal DataB folder) can later be
transferred to a connected PC or to an external memory (USB memory).
You can transfer to a USB memory device either individual files with
measurement data or all files stored in the internal Internal DataB folder.
z Individual files (see section 4.12.1)
z All files (see section 4.12.2)
Measurement data Save, back up, export
Concentration,
Absorbance / %
Transmission
Multi wavelengths
Measurement datasets of these measuring
modes are first stored in the measured value
memory of the photometer (1000 memory
locations) with <STORE> or AutoStore.
The measured value memory is available
from the Measurement data memory menu.
Here you can view, filter and export into a PC-
readable file (*.csv) the stored measurement
datasets (<STORE>).
Csv files of these measuring modes cannot
be reimported to the photometer.
Spectrum
Kinetics
You can store and export measurement data
of these measuring modes directly as a PC-
readable file (*.csv) with <STORE>.
Csv files of these measuring modes can be
reimported and displayed on the photometer.
AQA records You can store and export measurement data
of these measuring modes directly as a PC-
readable file (*.csv) with <STORE>.
Csv files of records cannot be reimported to
the photometer.