Owner's manual
Table Of Contents
- 1 Overview
- 2 Safety instructions
- 3 Commissioning
- 4 Operation
- 4.1 Switching on or off the photometer
- 4.2 General operating principles
- 4.3 Photometer settings and system administration
- 4.4 Zero adjustment
- 4.5 Measuring in Concentration mode
- 4.5.1 Measuring cell tests with barcode
- 4.5.2 Measuring reagent tests with AutoSelector
- 4.5.3 Measuring reagent-free tests and user-defined methods
- 4.5.4 Exceeding the upper or lower limits of the measuring range
- 4.5.5 Selecting a method manually
- 4.5.6 Settings for Concentration mode
- 4.5.7 Measuring diluted samples
- 4.5.8 Sample blank value
- 4.5.9 Reagent blank value
- 4.5.10 Automatic Turbidity correction
- 4.5.11 Programming / modifying user-defined methods
- 4.5.12 The IQ LabLink procedure
- 4.6 Measuring the Absorbance / % Transmission
- 4.7 Multi wavelengths methods
- 4.8 Spectrum
- 4.9 Kinetics
- 4.10 Timer
- 4.11 Memory
- 4.11.1 Overview
- 4.11.2 Instructions on using USB memory devices
- 4.11.3 Measurement datasets
- 4.11.4 Saving measurement datasets manually
- 4.11.5 Saving measurement datasets automatically
- 4.11.6 Displaying measurement data memory
- 4.11.7 Filtering measurement datasets
- 4.11.8 Inverting filters
- 4.11.9 Erasing stored measurement datasets
- 4.12 Copying files
- 4.13 Transmitting data
- 4.14 Analytical quality assurance (AQA)
- 4.15 User management
- 4.16 Reset
- 4.17 Photometer information ([Info])
- 4.18 Lamp counter
- 4.19 Software and methods update
- 5 Maintenance and cleaning
- 6 What to do if ...
- 7 Technical data
- 8 Accessories and options
- Appendix

photoLab
®
6100 VIS Operation
123
ba75847e01 08/2009
Configuring the lock
of the photometer
Here you configure whether or not the photometer will be locked against all
measurements if there is no valid AQA1 check or the interval for the AQA1
check has expired.
Configuration of
tests ...
1 Select and confirm Yes.
The photometer is locked against
all measurements if the AQA1
check is invalid or the AQA1
interval has expired.
<HOME>
[AQA]
– AQA1 setup
– Lock instrument
AQA1 setup
04/16/07 9:52
Mode Weeks
Interval
Lock instrument
Configuration of tests ...
Lock instrument
Should the instrument be locked for further
measurements if AQA1 check is invalid or
has expired?
No
Yes
All possible test standards or test
standard sets are listed.
1 Select and confirm a test standard
or test standard set.
2 Adjust and confirm the extent of
the monitoring with Activate or
Deactivate.
3 Confirm the test standard (set)
once again.
4 Switch to the adjustment of the
nominal values and tolerances
with Setup
.
<HOME>
[AQA]
– AQA1 setup
– Configuration of tests ...
AQA1 setup
04/16/07 9:52
PhotoCheck Active
CertiPUR UV-VIS 1 Inactive
CertiPUR UV-VIS 1A Inactive
CertiPUR UV-VIS 2 Inactive
CertiPUR UV-VIS 3 Inactive
CertiPUR UV-VIS Inactive
I
Apply
CertiPUR UV-VIS 1
General setup
Activate