User Manual
Global Water
800-876-1172 • globalw.com
- 5 -
V. Specifications
Power: AC: 115 VAC, 60 Hz or 230 VAC, 50 Hz (± 20%), 1.7 VA
DC: 12 to 30 VDC, 0.07 Amps max. @ 24 VDC
Outputs: Signal: 4-20 mA, 6.1 uA resolution; 750 ohms
Communication: Optional RS232 or RS485
Accuracy: ±0.25% of maximum sensor range (in air)
Frequency: 6.3 GHz (or 5.8GHz CE)
Measurement Range: 10” to 50’ (0.254 meters to 15.2 meters)
Resolution: 0.22in (5.7mm)
Transmitter Power: 50 uW average
Calibration: Push-button or optional programmable
Antenna: Polypropylene over dielectric rod
Beam Angle: 12 degrees
Operating Temp: -40°C to 60°C (-40°F to 140°F)
Operating Pressure: 150 psi max
Installation Category: Class II
Process connection: 2” NPT
Conduit Entry: 1/2” NPT standard
Housing: Aluminum or 316L stainless steel
Ingress Protection: NEMA 4 (IP65)