Owner manual

Operating instructions
WTS 102/3-en
16
9. Air pocket in pipeline
vent
improve course of pipe
10.
NPSH of system too small
increase liquid level
11.
Air being sucked in
increase liquid level
12.
Direction of rotation is wrong
swap over two phases of power supply (to be done by a specialist electrician)
13.
Inner components suffering from wear
replace worn parts
14.
Density and/or viscosity of liquid handled is too high
seek assistance
15.
Impeller out of balance
remove blocks/deposits
replace if broken or unevenly worn
check shafts to ensure that they are running true
16.
Coupling distance too small
change
17.
Forces in pipeline too high (pump unit under strain)
change (support pipes, use compensators, etc.)
18.
Too much, too little or the wrong type of lubricant
change
19.
Electricity supply not right
check voltage of all phases (2-phase running)
check cable connections
check fuses
20.
Bearing damaged
replace
check lubricant and bearing space for pollutants (rinse oil area)
21.
Discharge too small
increase minimum amount carried (open slide valves, bypass)