Refer to the values for adjustment
After the adjustment is finished, perform step
2. Wait until
ADJUST SUCCESS is shown and
press OK to complete calibration.
If the value shown is always
999,999,999,
follow the steps below to clean.
A. Clean the surface of the print head using the
copper brush.
(Clean the contact point between the print head
and print bed)
B. Wipe and clean the measurement points in
reference with Figure 4.
C. Perform the calibration process again.
烋
Reminder
I. Adjust the screw at Point A to reduce
the difference between the 1st and the
2nd measurements.
II.Adjust the screw at Point B based on
your evaluation of the results obtained
from the previous steps.
View the printer from the front when making
adjustment
Each turn leads to a
change of 50 to the
value shown
Rotate the screw to
the left to raise the bed
(value increases)
Rotate the screw to the
right to lower the bed
(value decreases)
4
5
;
<
=
Location of the
PHDVXUHPHQWSRLQWV
Adjust the location
of the screws
$%
&
Print Bed Adjustment Instructions