Operation Manual

Page 77FT-450 OPERATION MANUAL
MENU MODE
MENU FUNCTION AVAILABLE VALUES DEFAULT SETTING
CWSPEED 4 wpm (20cpm) ~ 60 wpm (300cpm) 12wpm (60cpm)
CWSTONE (CW SIDE TONE) FIX0 ~ FIX100 or LNK-50 ~ LNK0 ~ LNK+50 FIX10 or LNK-8
CWTRAIN (CW TRAINING) N: / A: / M: N:
CWWEIGT (CW WEIGHT) 1/2.5 ~ 1/4.5 1/3.0
D DISP (DATA DISP) -3000 ~ 0 ~ +3000 (Hz) 0
D TYPE (DTAT MODE) RTTY / USER-L / USER-U RTTY
DIALSTP (DIAL STEP) SSB/CW:1/10/20 (Hz), AM/FM:100/200 (Hz)
SSB/CW:10,AM/FM:100
DIG VOX OFF / 1 ~ 100 OFF
EMERGEN (EMERGENCY) ON / OFF OFF
KEYHOLD (KEY HOLD TIME) 0.5 / 1.0 / 1.5 / 2.0 1.0
LOCKMOD (LOCK MODE) FREQ / PANEL / ALL FREQ
M-TUNE ON / OFF ON
MEM GRP (MEMORY GROUP) ON / OFF OFF
MEM TAG TAG-OFF / TAGNAME TAG-OFF
MIC EQ 0 ~ 9 0
MICGAIN LOW / NOR / HIGH NOR
MICSCAN (MIC AUTO SCAN) ON / OFF ON
MY BAND ON / OFF ON
MY MODE ON / OFF ON
P M-DWN (MIC-DWN PG) One of 52 functions (See page 16) DWN
P M-FST (MIC-FAST PG) One of 52 functions (See page 16) N/A
P M-UP (MIC-UP PG) One of 52 functions (See page 16) UP
PEAKHLD (METER PEAK HOLD ) ON / OFF ON
PNL-C.S (PANEL’S CUSTOM SWITCH) One of 52 functions (See page 16) VCC
QSPL F (QUICK SPLIT FREQ) -20 ~ 0 ~ +20(KHz) +5
RFPOWER (RF PWR SET) 5 ~ 100 100
RPT (REPEATER SHIFT DIRECTION) - SHIFT / SIMPLEX / +SHIFT SIMPLEX
RPT SFT (REPEATER SHIFT OFFSET) 0 ~ 9.99
HF: 0.10 / 50M:1.00
RTY SFT (RTTY-SHIFT) 170 / 200 / 425 / 850 170
RTY TON (RTTY-TONE) 1275 / 2125 (Hz) 2125
RTYRPOL (RTTY-RX-POLARITY) NOR / REV NOR
RTYTPOL (RTTY-TX-POLARITY) NOR / REV NOR
SCN RES (SCAN RESUME) BUSY / TIME 1 ~ 10 TIME5
SELDIAL (SEL DIAL MODE) CWSTONE / CWSPEED / 100KHz /1MHz
100KHZ
/ MICGAIN / RFPOWER
SQL TYP (SQL TYPE) OFF / ENC / ENC DEC OFF
SQL/RFG (SQL/RF GAIN) SQL / RF GAIN RF GAIN
STBY BP (STBY BEEP) ON / OFF OFF
TONE F (TONE FREQ) 67 ~ 254.1 (Hz) 88.5 (Hz)
TOT (TOT TIME) OFF/1 ~ 20 (Min) OFF
TUNER (TUNER/ATAS) ATAS / EXT ATU / INT ATU
/ INTRATU / F TRANS
INT ATU
VOX DLY (VOX DELAY) 100 ~ 3000 (mSec) 500 (mSec)
VOXGAIN 1 ~ 100 50