Operation Manual

FT-60R/E OPERATING MANUAL72
Set Mode Item 17
[
DT WRT
]
Function: Programming of the DTMF Autodialer.
See page 54 for details.
Set Mode Item 18
[
EAI
]
Function: Enables/Disables the Emergency Automatic ID (EAI) Feature.
Available Values:
INT. 1M - INT.10M, INT.15M, INT.20M, INT.30M, INT.40M, INT. 50M,
CON. 1M - CON.10M, CON.15M, CON.20M, CON.30M, CON.40M, CON. 50M, and
OFF
Default: OFF
Set Mode Item 19
[
EDG.BEP
]
Function: Enables/Disables the Band-edge beeper while selecting the frequency via the
DIAL knob.
Available Values: BEP.OFF/ BEP. ON
Default: BEP.OFF
Set Mode Item 20
[
EMG S
]
Function: Selects the alarm(s) utilized when the Emergency function is engaged.
Available Values: EMG.BEP/EMG.LMP/EMG.B+L/EMG.CWT/EMG.C+B/EMG.C+L/
EMG.ALL/OFF
Default: EMG.B+L
EMG.BEP: Loud “Alarm” sounds.
EMG.LMP: The LCD/Keypad lamp flashes.
EMG.B+L: Loud “Alarm” sounds and the LCD/Keypad lamp flashes.
EMG.CWT: Transmits the Morse Code “SOS” (••• – – –•••) message on the air beginning
one minute after activation of the Emergency function.
EMG.C+B: Loud “Alarm” sounds and the Morse Code “SOS” (••• – – –•••) message is
transmitted on the air beginning one minute after activation of the Emer-
gency function.
EMG.C+L: The LCD/Keypad lamp flashes, and the Morse Code “SOS” (••• – – –•••)
message is transmitted on the air beginning one minute after activation of the
Emergency function.
EMG.ALL: All of the above are activated.
OFF: Disables the Emergency function. The Emergency function also cannot be
engaged, by pressing and holding in the
[
4
(
RPT
)]
key, if this Menu is set to
“OFF.”
When the radio is set to the EMG.CWT, EMG.C+B, EMG.C+L, or EMG.ALL mode, the
radio will be instructed to send “DE (your callsign)” after the sending of the SOS mes-
sage, if your callsign is entered via Set Mode Item 11: CW WRT.
SET
(
MENU
)
M
ODE