Operation Manual

FT-60R/E OPERA TING MANUAL 73
Set Mode Item 21
[
I NET
]
Function: Selects the Internet Link Connection mode.
Available Values: INT.OFF/INT.COD/INT.MEM
Default: INT.OFF
INT.OFF: Disables the Internet Link Connection mode.
INT.COD: Sets up the Internet Link Connection mode for WiRES™ access.
INT.MEM: Sets up the Internet Link Connection mode for other (DTMF string) Internet
Link System access.
Set Mode Item 22
[
INT CD
]
Function: Selects the Access Number (DTMF digit) for WiRES
TM
operation.
Available Values: CODE 0 - CODE 9
Default: CODE 1
Set Mode Item 23
[
INT MR
]
Function: Selects the memory register for an Access Number (DTMF code) for non-
WiRES™ Internet Link System access.
Available Values: d1 - d9
Default: d1
Set Mode Item 24
[
LAMP
]
Function: Selects the LCD/Keypad Lamp mode.
Available Values: KEY/5SEC/TOGGLE
Default: KEY
KEY: Illuminates the Keypad/LCD for five seconds when you rotate the DIAL knob
or press any key or switch (except the PTT switch).
5SEC: Illuminates the Keypad/LCD for five seconds when you press the LAMP switch
momentarily.
TOGGLE: Toggles the Keypad/LCD lamp on and off when you press the LAMP switch
repeatedly.
Set Mode Item 25
[
LOCK
]
Function: Selects the Control Locking lockout combination.
Available Values: LK KEY/LKDIAL/LK K+D/LK PTT/LK P+K/LK P+D/LK ALL
Default: LK K+D
Note: “K” = “Key;” “D” = “Dial;” and “P” = “PTT.”
SET
(
MENU
)
M
ODE