Extra Information

39
FT-70DR/DE Advance Manual
48 RXSAVE
Set receiver battery save operation.
Sets the Receive battery save OFF time interval (sleep ratio) to reduce power con-
sumption.
OFF Disables the Battery save function.
0.2 S – 60.0 S
Enables the battery save function. Receiving is automatically
OFF during the set time, no signal is heard.
0.2 S: 0.2 sec receive/0.2 sec receive OFF (1:1).
60.0 S: 0.2 sec receive/60 sec receive OFF (1:300).
z
With the longer value of the battery saving, a short transmission or the beginning of a
message may not be heard. Adjust the setting according to the operating considerations.
z
Set the battery save function “OFF” when using the DP-ID function in the Voice FR (VW)
mode.
49 SCM.WTH
Set the memory scan frequency range.
Set the frequency band range while scanning in the memory mode.
ALL
All the memory channels are scanned without regard to the
band of the registered frequency of the memory channels.
BAND
Only memory channels with frequencies registered to the
same band as the channel on witch scan is started are
scanned.
VHF
(
1
)
144MHz band
430MHz band UHF
(
1
)
AIR band
VHF
(
2
)
108
137MHz 137
174MHz 174
222MHz 222
420MHz 420
470MHz 470
580MHz
50 SCV.WTH
Set the VFO scan frequency range.
Sets VFO scanning action, when the scanning reaches the end of a frequency band.
ALL
When scanning reaches the band edge, scanning continues into
the next frequency band.
VHF
(
1
)
144MHz band
430MHz band UHF
(
1
)
AIR band
VHF
(
2
)
108
137MHz 137
174MHz 174
222MHz 222
420MHz 420
470MHz 470
580MHz
BAND
When scanning reaches the band edge, scanning repeats
within the same frequency band.
VHF
(
1
)
144MHz band
430MHz band UHF
(
1
)
AIR band
VHF
(
2
)
108
137MHz 137
174MHz 174
222MHz 222
420MHz 420
470MHz 470
580MHz