Extra Information

40
FT-70DR/DE Advance Manual
51 SCN.LMP
Set back light ON or OFF when scanning stops.
Sets the back-light operation when a received signal pauses the scan.
OFF The back light does not illuminate when scan stops.
ON When stops scanning temporarily, the back light turns ON.
52 SCN.RSM
Set scan resume condition
When receiving the signal and pausing the scanning, select the receive operation.
2.0 S –
5.0 S
10.0 S (SEC)
The signal is received for a specified period of time, and then
scanning resumes.
BUSY
Scanning stops on a received frequency until the signal fades
out. Two seconds after the signal fades out, scanning re-
sumes.
HOLD
Scanning stops on the current receive frequency (Scanning
does not resume). Scanning may be resumed manually.
For more details, see “Setting the Receive Operation When Scanning Stops” (Oper-
ating Manual).
53 SCN.STR
Set the scanning restart time.
Set the time interval to resuming scanning after a received signal halts scanning.
0.1 S –
2.0 S
10.0 S (SEC)
Sets the time for scan to resume after the received signal ends
during scanning.
For more details, see “Setting the Receive Operation When Scanning Stops” (Oper-
ating Manual).
54 SQL.EXP
Set the squelch code separately for Receive and transmit.
Applies the squelch codes separately for TX and RX or simultaneously for both TX
and RX.
SPL.OFF
Sets squelch codes (“D CODE” / “T DCS” / “D TONE”), sepa-
rately for TX and RX.
SPL.ON
Sets squelch codes (“D CODE” / “T DCS” / “D TONE”)
simultaneously for TX and RX.
For more details, see “Selecting the Squelch Type in the Analog FM Mode” (
7).