Operation Manual

21FT-7900R OPERATING MANUAL
FREQUENCY NAVIGATION
1
)
Tuning Dial
Rotating the DIAL knob allows tuning in the pre-programmed steps established for the VFO
frequency. Clockwise rotation of the DIAL knob causes the FT-7900R to be tuned toward a
higher frequency, while counter-clockwise rotation will
lower the operating frequency.
Press the
[
MHz
(
PRI
)]
key momentarily, then rotate the
DIAL knob, to change the frequency steps to 1 MHz per
step. This feature is extremely useful for making rapid
frequency excursions over the wide tuning range of the
FT-7900R.
2
)
Direct Keypad Frequency Entry
(
MH-48A6J Microphone
)
The keypad of the MH-48A6J DTMF Microphone may be used for direct entry of the oper-
ating frequency.
To enter a frequency from the MH-48A6J keypad, just press the numbered digits in the
proper sequence. There is no “Decimal point” key on the MH-48A6J keypad.
Examples: To enter 146.480 MHz, press
[
1
]
[
4
]
[
6
]
[
4
]
[
8
]
[
0
]
To enter 433.000 MHz, press
[
4
]
[
3
]
[
3
]
[
0
]
[
0
]
[
0
]
3
)
Scanning
From the VFO mode, press and hold in the
[
SCAN
(
SEL
)]
key for 1/2 second, then rotate the
DIAL knob to select the bandwidth for the VFO scanner. Now, press the
[
SCAN
(
SEL
)]
key
momentarily to initiate scanning toward a higher frequency. The FT-7900R will stop when it
receives a signal strong enough to break through the squelch threshold. The FT-7900R will
then hold on that frequency according to the setting of the “Resume” mode (Menu #37 (
SCANSCAN
SCANSCAN
SCAN);
see page 75). See page 43 for details regarding the VFO Scan operation.
If you wish to reverse the direction of the scan (i.e. toward a lower frequency, instead of a
higher frequency), just rotate the DIAL knob one click in the counter-clockwise direction
while the FT-7900R is scanning. The scanning direction will be reversed. To revert to scan-
ning toward a higher frequency once more, rotate the DIAL knob one click clockwise.
Press the
[
SCAN
(
SEL
)]
key (or the PTT key) again to stop scanning.
You may also initiate the scanner by pressing and holding in the microphone’s
[UP] or [DWN] key. However, in this case, the scanner will sweep frequencies
only on the current band. If you would like the scanner not to be restricted to the current
band, you may change Menu #46 (VFO.BND) to allow the scanner to hop to the low edge
of the next-highest band when the VFO frequency reaches the high end of the current
band (or vice- versa). See page 77 for details.