User manual
5.2 Lamp adjust
The lamp holder is aligned at the factory. Due to differences between lamps , fine
adjustment may improve light performance. Strike the lamp, open the shutter and the iris,
set the dimmer intensity onto 100% and focus the light on a flat surface (wall). As the
optimum distance of the lamp from lens was adjusted during the installing or changing the
lamp (by turning the screw ), it is necessary to adjust only the second position by
turning the screw , in order to center the hot-spot (the brightest part of the beam). If
the hot spot seems to be too bright, you can lower its intensity by moving the lamp closer to
the reflector. Do so by turning the screw until the light is evenly distributed. If the
light on the edge seems to be brighter as in the center, the lamp is too close at the reflector.
In this case, you need to move the lamp away from the reflector until the light is evenly
distributed and the beam appears bright enough.
"A"
"B"
"A"
1-1,5 mm
Optimum distance
Screw B
“”
Screw A
“”
Correct
WARNING!
Lamp is hot! Risk of fire! Protect hands and eyes.
Wait at least 15min. Before opening the covers
and removing lamp from the fixture.
Minimum distance to lighted object:
Maximum room temperature t=45
Minimum distance from flammable material d=0.5m.
Exterior surface temperature T=80 .
Not for domestic use.
℃
℃
Be sure that the lamp
bulb never touch the lens
Disconnect the fixture from AC power
before re-lamping.
A
B
A
djust lamp position by turning screws and
Incorrect
Turn off the lamp and allow it to cool for at least 10 minutes. Disconnect the fixture from
power. To insert the gobos open the top cover of the moving-head by loosening the 3 screws
on the top cover and follow the instructions below:
Press the ends of the fixation-ring together with an appropriate tool and remove it.
Remove the gobo and insert the new gobo. Press the ends of the fixation-ring together and
insert it in the front of the gobo.
Rotating gobo-wheel:
5.3Inserting/Exchanging gobos