6-4 Laser Aiming Device (LAD™) Operation Studio Spot
®
250 / Studio Color
®
250 User Manual
You might need to realign the laser periodically in order to maintain its optimal
position. However, the decision of whether or not to align the laser is entirely up to
you. If the laser strays from its optimal position, but it gives you enough accuracy for
your needs, you do not have to align it.
Alignment Procedure
You can use either the fixture’s on-board menu system or your DMX controller to
complete the alignment procedure below.
1. Physically orient the fixture so the beam will point toward a white wall no less
than 10 ft. (3 m) away (see
Figure 6-4).
Figure 6-3. Ideal position of the laser.
3.3 in. (8.4 cm)
Studio Spot 250 fixture
Studio Color 250 fixture
3.5 in. (8.9 cm)
Figure 6-4. Orient the fixture for laser alignment.
10 ft. (3 m) minimum
sturdy
surface
white wall