User manual

7-2 General Maintenance Studio Spot
®
250 / Studio Color
®
250 User Manual
2. Determine which fuse to replace by referring to Table 7-1.
3. Using a wide-tip, flat head screwdriver, loosen the two panel cover retaining
screws on each side of the fixture and remove the fixture’s two panel covers (see
Figure 7-1).
Table 7-1. Description and Function of Fuses
Fuse Type and Rating Size Protects Symptom of Failure
F1
6.3 A, 250 V, Fast
Blow only
5mm x 20mm
Motor supply and fan
supply
If the fixture is operating normally
and this fuse blows, the LAD (if
applicable) and the lamp will turn
off, the motor LED will be off, and
the motors will not move. If
power is cycled when this fuse is
already blown, the LED
alphanumeric display panel will
remain blank.
F2
2.5 A, 250 V, Fast
Blow only
5mm x 20mm Logic board
Fixture shuts down, motor LED
may be on.
F3
6.3 A, 250 V, Slow
Blow only
5mm x 20mm Main fuse
Fixture shuts down, all status
LEDs are off, the fixture will not
receive power.
two panel retaining screws two panel covers
Figure 7-1. Remove the two panel covers.