User manual

Studio Spot
®
250 / Studio Color
®
250 User Manual Troubleshooting 8-3
8
LAMP
TOUT
ERR
Lamp is too hot to restrike.
Failed lamp.
Ignitor failure.
Allow 5 to 10 minutes for the lamp to cool, and attempt
to restrike the lamp (see
“Turning the Lamp On or Off
(LAMP)” on page 4-30).
Replace the lamp (see “Replacing the Lamp” on page
7-4).
Contact High End Systems customer service (see
“Contacting High End Systems” on page ii).
LINK
BUSY
Controller or other
crossloading fixture is
communicating on the link.
Serial data distributor,
optoisolator, controller, or
fixture using RS-422
communication is located
before Studio Spot 250 or
Studio Color 250 fixtures on
the link.
Preset playback is on, and
the master fixture detected
other activity on the link and
stopped transmitting time
code.
Disconnect controller or wait for other crossloading
fixture to finish crossloading.
Remove or bypass the offending device(s) on the data
link and reattempt the crossload.
Verify that no other fixture is assigned DMX start
channel 1 or fixture number 1 except the master
fixture.
Three minutes after the last activity on the link was
detected, the master fixture will attempt to resend the
time code.
LINK
EMTY or
LINK ERR
The crossloading fixture
experienced a communication
failure with other fixtures due
to:
Bad cable(s).
No data or bad data.
Output from previous fixture
was bad.
Bad comm board.
Test and replace cable(s) as necessary.
Test controller data on another link.
Test by bypassing previous fixture on the link.
Contact High End Systems customer service (see
“Contacting High End Systems” on page ii).
OVER
Lamp strikes, lamp hours, or
fixture hours have exceeded
the limited range of 9999.
Reset the menu item that has rolled out of range (see
“Resetting Lamp Hours (L/RS)” on page 4-39, or
“Resetting Fixture Hours (F/RS)” on page 4-38).
PCB
TEMP
ERR
The internal temperature of
the fixture’s logic board is
too high.
Make sure the fixture’s fan is working by placing your
hand over the fan’s exhaust located on the rear panel.
If you do not feel air movement, the fan has failed.
Contact High End Systems customer service (see
“Contacting High End Systems” on page ii).
Remove any object which may be obstructing the fan
vents on the back of the rear panel.
Check and reduce ambient temperature by turning on
fans and/or moving the fixture if it is close to a heat
source.
Table 8-1. LED Error Messages
Display
Message
Problem Solution