250 User Manual Troubleshooting 8-5
8
THRM
PAN
The pan motor maximum
temperature was exceeded.
• Move the fixture if it is close to a heat source.
• Remove any object which may be obstructing the
fixture’s heatsink.
• Check and reduce ambient temperature by turning on
fans, etc.
THRM
TILT
The tilt motor maximum
temperature was exceeded.
• Move the fixture if it is too close to a heat source.
• Remove any object which may be obstructing the
fixture’s heatsink.
• Check and reduce ambient temperature by turning on
fans, etc.
TILT
CONN
The tilt sensor is not connected
Contact High End Systems customer service (see
“Contacting High End Systems” on page ii).
TILT DRV
ERR
• The tilt motor wire has
shorted to ground.
• Bad tilt driver chip.
Contact High End Systems customer service (see
“Contacting High End Systems” on page ii).
TILT
ENCD
The tilt encoder is not
connected or not functioning
properly.
Contact High End Systems customer service (see
“Contacting High End Systems” on page ii).
TILT ERR
• Loose tilt pinion gear.
• Loose tilt motor cable.
• Incorrect cabling to tilt input.
• Bad tilt sensor.
• Bad tilt motor.
Contact High End Systems customer service (see
“Contacting High End Systems” on page ii).
TILT
STOP
• There is a physical
obstruction blocking the tilt
movement.
• The tilt encoder is out of
calibration.
Remove the obstruction and home the fixture.
UPLD
The fixture is held in boot mode
because power was
disconnected during an upload.
Reconnect the fixture and perform the upload again or
contact High End Systems customer service (see
“Contacting High End Systems” on page ii)
Table 8-1. LED Error Messages
Display
Message
Problem Solution