Yale Real Living™ Touchscreen Deadbolt Installation and Programming Instructions NOTE TO INSTALLER FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN DAMAGE TO THE PRODUCT AND VOID THE FACTORY WARRANTY For Technical Assistance call Yale at 1-800-810-WIRE (9473) This document is available on our website in printed Spanish and French. Go to www.yalerealliving.com. Click “Product Information & Documentation” and then “Installation Instructions”.
TABLE OF CONTENTS Warnings...................................................................................................................... 2-3 Introduction......................................................................................................................3 Installation Components and Tools..............................................................................................4 Prepare Lock for Installation.........................................................................
Industry Canada: Canadian ID: 6982A-YRHCPZW0 (Z-Wave); 6982A-YRHCPZB0 (Zigbee) This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
INSTALLATION COMPONENTS AND TOOLS Included in the box. . .
PREPARE LOCK FOR INSTALLATION Unpack the Lock The lock is packed representative of how it will install on the door. Before installing the lock on the door: A. Inside escutcheon 1. Loosen the screw (Phillips #2) holding the battery cover. (The screw remains attached to battery cover) 2. Slide the battery cover up and out (note the two tabs at bottom of battery cover). 3. Remove the inside mounting plate (with gasket) from the back (door side) of the inside escutcheon.
INSTALL LOCK 1 1. Install bolt in door. NOTE: The bolt must be in a retracted (unlocked) position when installing the lockset. Attach with two (2) M4 x 25.4mm [8-32 x 1"] screws supplied. (2) M4 x 25.4mm [8-32 x 1"] Flat Head Combination Screws 2 2. Install strike on the door frame, making sure to allow for the bolt to be centered in the strike. (2) M4 x 25.4mm [8-32 x 1"] Flat Head Combination Screws 3. Install outside escutcheon.
CAUTION: Position and bend cable, using care when assembling to ensure that the cable lies against the back recessed area of the inside escutcheon. Label Use the cable hook (See label on circuit board) as shown in Figures 6A & 6C to prevent binding when installing the escutcheon over the mounting plate. Figure 6A 6. Attach cable assembly connector to the inside escutcheon PC board by lining up notches on top of cable connector to slots on PCB connector (Fig. 6B).
7. Install inside escutcheon on inside mounting plate. Note the horizontal orientation of the tailpiece (Fig. 7) as you insert the inside escutcheon; the thumbturn should be vertical. Figure 7 8. Install and secure using (3) M4 x 8mm [8-32 x 5/16"] pan head screws through the inside escutcheon into the mounting plate (Fig. 8). IMPORTANT: Before installing the batteries, test the mechanical operation of the lock by operating the thumbturn. The movement of the bolt should be smooth and unobstructed.
PROGRAMMING Programming Features-Menus-Keys-Definitions................................................ 9-10 Operation...........................................................................................................
Status Indicators 1 Low Battery Warning 2 All Code Lockout Mode 3 Return to previous step Definitions All Code Lockout Mode: This feature is enabled by the Master PIN code. When enabled, it restricts all user PIN code access (except the Master PIN code). When the unit is in Lockout Mode, the red locked padlock (see above) will appear on the screen when attempting to enter a PIN code.
OPERATION Lock Activation The touchscreen can be activated in several ways: Touch screen with back of hand or fingers to activate. Press the activate. Touch screen with fingers spread to activate. key to Register Master PIN Code Before Programming* 1. Touch the screen with the back of your hand or fingers to activate 2. Press the key. Lock Response: “Register Master Code; press the 3. Press the . key to continue.” key. Lock Response: “Enter a 4 to 8 digit PIN code followed by the pound key." 4.
To reset the lock to factory default, see the following: Reset Lock to Factory Default The following procedure returns the lock to its factory defaults by deleting all user codes (including the Master PIN code*) and returning all programming features to their original default settings (see below). Reset Button Cable 1. Remove the batteries and then remove the interior escutcheon to access the reset button. 2. The reset button (see image at right) is located above the PCB cable connector. 3.
PIN code structure Maximum number of user codes is 250 with Network Module; without Network Module, maximum is 25 user codes. Set Up User PIN Codes User PIN Codes can only be programmed through the Master PIN Code*. 1. Touch the screen with the back of your hand or fingers to activate . 2. Enter the 4-8 digit Master PIN code followed by the key. Lock Response: “Menu mode, enter number, press the key to continue.” 3. Enter “2” followed by the key. 4. Enter “1” followed by the key. 5.
Feature Programming Through Menu Mode Using Master PIN code* 1. Enter the 4-8 digit Master PIN code followed by the key. 2. Enter digit corresponding to the function to be performed followed by the key. Note: If the lock is connected to a network controller, it is recommended that it is programmed through the centralized user interface (PC or hand-held device) to ensure communication between the lock and the controller unit.
MISCELLANEOUS Hardware Troubleshooting.......................................................................................15 Programming Troubleshooting................................................................................16 Installing the Network Module ................................................................................17 Replace/Install Cylinder ..........................................................................................19 Sample Pin Code Management Sheets..........
Programming Troubleshooting Symptom Lock does not respond – door is open and accessible. Suggested Action The touchscreen will become active when pressed with the back of hand or fingers in at least 3 areas simultaneously. Use a larger area of the hand or fingers and verify contact with at least 3 areas. If touchscreen numbers are visible, check to see if they respond when pressed. Check batteries are installed and oriented correctly in the battery case.
Installing the Network Module IMPORTANT: The batteries must be removed prior to removing and/or inserting the network module: • Remove battery cover • Remove batteries • Remove and/or insert network module • Reinstall batteries Use feature programming step 7 (page 14) for enrollment of the Network Module.
How to Replace or Install Cylinder 1. Remove cylinder: A A. Remove outside escutcheon from door. B. Remove rubber gasket. C. Insert small flathead screw driver under spring; (gently) lift spring. B D. Note: notch on top of cylinder engages spring E. Remove cylinder by pulling (outward) towards outside of door. Before installing cylinder, please be sure tailpiece is correct length (see below). 2. Install new cylinder: A. Reverse previous steps for removing cylinder.
PIN CODE MANAGEMENT SAMPLE SHEETS PIN Code Management (No Network Module - Up to 25 Users) Location: User Type Door Number: User Name User # User User Name User # PIN Code PIN Code Master User 13 User 01 User 14 User 02 User 15 User 03 User 16 User 04 User 17 User 05 User 18 User 06 User 19 User 07 User 20 User 08 User 21 User 09 User 22 User 10 User 23 User 11 User 24 User 12 User 25 19 P/N AYRD220-INST-FUL Rev E An ASSA ABLOY Group brand
PIN Code Management (With Network Module - Up to 250 Users) - Duplicate Sheet to record entries User Type User Name User # PIN Code User Master User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ Us
ONLINE LITERATURE AND TEMPLATES For the latest information on Yale products visit our website at www.yalelocks.com. Click on the “Literature” button to find the most up-to-date catalogs, parts manuals, templates, specifications and installation instructions. Scan this code to view installation videos for this and other Yale Real Living products. Yale Locks & Hardware 100 Sargent Drive, NewHaven, CT 06511 • Product Support Tel 800.810.WIRE (9473) • www.yalelocks.