Yale 4202 2 Wire Video Intercom System USER MANUAL YDV4202-V1
Power Unit 1. Warning - Don’t dismantle or alter the unit. Fire or electric shock could result. - The unit must be installed and wired by a qualified technician. - Do not connect any non specified power source to the N, L terminals, Fire, damage to the unit, or system malfunciont can result. - Keep the unit away from water or any other liquid, risk of fire or electric shock. 2. Introduction: The power unit is designed for two wire systems.
4. Mounting: Step1: Mount the din rail to the wall with screws ; Step2: Pull down the lock release lever,then hang the unit on din rail. Din rail Din rail Lock release lever 5. Basic wiring (no lock): 2 BUS BUS (DS) (IM) NP NP: Non-polarized PA P- P+ L1 L2 N L 2 NP L1 L2 AC~ Note:PA&P+ terminal must be short-circuited. Input Voltage: Input Frequency: Rated Output Voltage: Rated Output Current: Working Temperature: SW Port Input Voltage: Dimension: 100~240Vac 50~60Hz DC 28V+/-2V 1.
Exterior Unit 1.Parts and Functions Camera Lens Speaker 176 mm Night View LED Nameplate Call Button Microphone Rain Cover 90 mm 23 mm 2.
• Lock Control Jumper: Not to be removed • Doorstation Code DIP: To be used when additional exterior units are used in the same system. • Main Connect Port: To connect the interior monitor and electornic lock/s. BUS: Connection to interior monitor, no polarity. PL: External lock power input, connect to the power positive(power +). S1+, S2+: Lock power(+) output. To locks can be connected through the unit.
5. Placing Name Label Remove the plastic cover to open the transparent name label holder, cut a paper to size print name. Insert paper on to name holder re insert plast cover back to the panel ON 1 2 Backside name label 6. Adjusting Camera Angle Use a screwdriver to loosen the screw. Adjust the desired anlge and then fix the screw back.
. Basic wiring (with electronic lock) ON 1 2 AC~ monitor BUS(IM) BUS(DS) BUS(DS) BUS PLS1+ S2+ S- BUS(IM) + Use supplied plugs to connect Exterior unit to Power unit, and Power Unit ot Interior Monitor.
Interior Monitor Introduction The monitor is designed with a 4 inch screen, it provides a resolution of 320x240 pixels with high quality image display, and it is equipped with a handset to communicate The touch sensitive button makes the operation easy.
Unit Mounting Accessory contents: 145~160 cm Accessories include a Bracket, two 4X25 screws (use to fasten the Mounting Bracket), 2 wire plug/connectors (use to connect with Monitor). Installation steps: Installation height for indoor monitor usually is 145~160cm (refer to sketch). Wire the cable correctly, then hang the Monitor on mounting bracket firmly. About Main Menu The main menu is your starting point for using all the applications on your monitor.
• Pick up handset to talk with the visitor, the talking duration time is 90s. To en the conversation, hang up the handset. If the system connects two or more monitors, puck up any handset, the others will be automatically shut off. Door Release During a call, press UNLOCK button to open the door for the visitor. Entrance Monitoring When the monitor is in standby mode, press MONITOR button (or select Monitor item on main menu page), The screen will display the outside image.
Direct Call Guard unit: A Monitor can be assigned as Guard Unit Monitor, so a intercom call can be placed directly to the Guard Unit Monitor. Intercom Call Intercom Intercom Call ... Inner Call ... Direct Call Guard Unit ... Exit OK Select Item [ 00 ] [ 01 ] [ 02 ] [ 03 ] [ 04 ] [ 05 ] Joe Alex Mike Susan Mary Tony Exit xt Calling Next Page Basic Setup Instruction Ring Tone Setting Select User Setup item on main menu page to enter setup page.
Screen Setting Scene Bright Color Select Camera ... During a c a l l o r w h e n monitoring ouside, press MENU button, the adjust menu will be displayed. Use / button to select the adjust menu item, use M E N U button to change values. Brightly 6 6 Exit Select Item Inc • The item is Scene mode selection: Total of 4 screen modes can be selected: Normal, User, Soft and Bright.
How to set the monitor as a Guard Monitor A Monitor can be assigned as Guard Unit Monitor. A call can be placed directly to the Guard Unit Monitor, bypassing the Intercom Menu. The code 8004 is used to set the monitor as a guard unit monitor and 8005 to cancell this function.
2 locks control: The monitor can be set to control 2 locks while you should set the unlock2 item to "on " state. The code number of 8015 is used to set the unlock2 OFF. This setting is for only one lock. The code number of 8014 is used to set the unlock2 ON. This setting is to control two locks. Note: During a call or while monitoring outside, press UNLOCK button. Two unlock icons will be showed.
How to set the address for monitor Each monitor should be assigned an address in the system, total 32 addresses can be assigned. Code numbers from 8200 to 8231 are used as address 00 to 31. Please refer to following table: Input No. User Code Input No. User Code Input No.
Specifications • • • • • • • Power Supply: Power Consumption: Monitor Screen: Display Resolutions: Video Signal: Wiring: Dimension: DC 24V Standby 6mA; Working status 194mA 4 Inch color LCD 320(R, G, B) x 240 pixels 1Vp-p, 75Ω, CCIR standard 2 wires, non-polarity 186(H)×190(W)×26(D)mm Precautions 1) All components should be protected from drops and vibrations. Do not drop unit. 2) To clean, use a soft cotton cloth. If necesary, use mild soap and water to wash lightly.