Specifications
2
Keyfob remote control accessory 
Can be used outside the premises and 
kept on your keyring. 
Location planning
Operating range 
All devices must be within 30 metres of the siren unit and must 
not be mounted on or near large metal objects. Avoid obvious 
sources of electrical interference such as fridges and microwave 
ovens. 
Tamper switches 
When mounting devices ensure that any tamper switches close 
fully. On uneven surfaces it may be necessary to place packing 
behind the switch for reliable operation. 
1
Work out the best places to locate the devices for maximum protection. Having chosen the 
locations do not mount at this stage.
Smoke detector 
• Mount in the middle of the ceiling at the top of 
a stairwell, or on the centre of hallway ceilings 
where smoke would most likely be detected.
• Do not mount in corners or above cooking 
appliances and heaters.
• Install additional detectors if there are closed 
doors preventing smoke from reaching 
detectors.
Siren 
Choose a position on an external wall where the
siren would be most prominent. Mount as high
as possible, out of easy reach. (Round shaped siren shown)
Keypad remote control 
• The keypad should be sited next to the main point of entry/
exit so that the system can be disarmed/armed within 20 
seconds of entering/leaving the premises. 
• Ensure that the keypad is not visible from the outside of the 
premises. 
• Mount at chest height for ease of use. 
• Designed for indoor use only.
Help button accessory 
The help button provides extra protection 
for you and your family. When help is 
needed the button can activate your alarm 
immediately - even when the system is 
disarmed. 
•  Mount on at wall surface
•  Designed for indoor use only
•  Out of reach of children
•  Hidden from view while easily accessible.
Extend the system 
Extend the system in the future to increase your security or as 
your needs change. 
For example, add extra PIR detectors in bedrooms and extra 
door/window contacts (20 devices in total, including keypad). 
PIR movement detectors 
• Mount in a position such that an intruder would normally move 
across a PIRs field of view. 
• Height should be between 1.9 and 2 metres above oor level. 
• Location in a corner will ensure wider room coverage. 
• Do not mount a PIR where its eld of view will be obstructed e.g. 
by curtains, ornaments etc. 
• Do not point directly at sources of heat e.g. res or boilers, and do 
not position directly above radiators. 
• Avoid mounting a PIR directly facing a window. 
• Do not point a PIR at a door protected by a door/window contact.
Yale
R
ale
Y
Door/Window contacts
Use one door/window contact on a door 
that is used as the main point of entry and 
exit, usually your front door. The other 
door/window contact can be used to 
protect 
another entry point such as a rear door. 
• Mount as high as possible. 
• Do not aim a PIR at this door or window. 