Specifications
8
Arming the system
Keypad/Keyfob: Press arm 
(The siren will beep/flash once. No audible countdown.)
Disarming the system
Keypad: Press disarm followed by your pincode.
Keyfob: Press disarm.
(The siren will beep twice and flash.)
Stopping the Siren
Keypad: Press disarm followed by your pincode.
Keyfob: Press disarm.
(The siren will be silenced and then beep twice and flash.)
Changing your keypad PIN code
1 Enter setting mode: Press the Panic button A, 
followed by entering the current pincode (factory 
default code is 0000). 
 (The LED will now flash continuously.)
2 Press panic button B.
3 Enter new 4-digit pincode.
4 Press Arm button to confirm.
5 Exit setting mode: Press disarm twice to quit the 
changing code process. Or wait for 5 minutes for 
the keypad to quit test mode automatically.
  (The LED will now stop flashing.)
Tamper alarm warning
If any device tamper switches are disturbed a 
tamper alarm will be activated with the siren 
sounding and the strobe ashing. The alarm can be 
silenced as described in “Stopping the Siren”. 
Previous alarm warning
Should there be an alarm that was triggered and 
expired (while the user was away), the siren will 
sound and ash for 3 seconds after disarming (user 
returning home).
* Warning: should this happen the intruder could still 
be in the premises.
My PIN code:
(write your pincode here so you don’t forget it)
Using the system
Arm and disarm the system and practice using it. Trigger the alarm by arming the system 
and opening protected doors/windows and walking past PIRs. Now’s the time to set your pin 
code and show the rest of the family how simple it is to use.
5
• Keypad will arm the system with a 20 seconds 
 exit period. All detectors will be ignored (except  
 for the tamper switches). The system can be 
 armed when inside the protected area of your
 premises.
• Keyfob will arm the system instantly without a 
20 second exit delay. Any detector activated 
afterwards will trigger an instant alarm. The 
system should be armed when outside the 
protected area of your premises.
i
• Keypad: If the system has been armed with a 
keypad there will be a 20 second entry period 
started when the first detector is activated 
(usually a window/door contact on the main 
point of entry). During this entry period all 
detectors will be ignored.
• If the system is not disarmed before the entry 
period expires, the alarm will be activated.
• The system does not have an audible 
countdown during the entry period, however 
the siren will beep once when the first detector 
is triggered.
• Keyfob: If the system has been armed with a 
keyfob there will be no 20 second entry period 
and any detector activation will give an instant 
alarm.
• The system should be disarmed from outside 
the protected area of your premises.
i
• If the PIN code doesn’t change, repeat the 
above procedure quickly without gaps.
i
  If there is a persistent siren tamper fault then a 
series of 5 pips and ashes will be given when 
the system is armed, then the siren should be 
checked for any mounting problems and if the 
siren lid is secure. Use packing material for 
uneven wall surface.
i
The PIRs have a built-in sleep timer to save
battery power. If there is no movement in front
of the PIRs for 1 minute, the PIRs will become
‘ready to signal’ and movement will now be
reported. The PIRs will sleep for 1 minute after 
reporting.
Any movement detected in sleep time will not be
reported and will extend the sleep period by a
further 1 minute.
i