Yale Assure Lock Push Button Deadbolt Installation and Programming Instructions (YRD216/YRD416) ® ® ® Optional Network Module Before you begin DOWNLOAD THE BILT APP for step-by-step installation instructions & to register your product x3 #8-32 x 5/16" Machine screws x4 #7 wood & #8-32 machine x 20mm Combination screws x2 M6x59.
Preparing Door 2 P/N YRL-PBINSTL-FUL Rev E
1 Installing Latch & Strike Plate 2-3/8" position defaut x4 2-3/4" position O optional Pull Press Bolt must be in retracted (unlocked) position. Note horizontal orientation of mechanism.
2 Installing Keypad Escutcheon Inside of Door Outside of Door Bolt must be in retracted (unlocked) position. Note horizontal orientation of mechanism.
3 Installing Interior Mounting Plate Loosen screw to remove cover.
4 Attaching the Cable Assembly 6 P/N YRL-PBINSTL-FUL Rev E
5 Installing Interior Escutcheon x3 7 P/N YRL-PBINSTL-FUL Rev E
Testing Operation 3 Bolt must be in retracted (unlocked) position before installing batteries.
Testing Operation 2 9 P/N YRL-PBINSTL-FUL Rev E
6 Installing Optional Network Module 7 Installing Batteries & Cover Tighten screw to replace cover. Congratulations, you've installed the Yale Assure Lock Push Button Deadbolt (YRD216)! Continue with Programming Instructions to customize your product.
Programming Instructions Low Battery WarningFlashes RED Lock-out ModeKeypad Flashes Privacy Mode Button Exterior Escutcheon Interior Escutcheon Master PIN Code must be created before any further programming. Max User Codes = 250 with Network Module. Max User Codes = 25 without.
1 Creating Master PIN Code Press Press Press Enter 4-8 digit Master PIN Code.
2 Creating User PIN Codes Master PIN code must be created first. *Max User Codes = 250 with Network Module. Max User Codes = 25 without.
3 Unlocking Door with PIN Code Enter PIN Press "Unlock" Code Chart Duplicate if necessary PIN Code Management (With Network Module - Up to 250 Users) User Type User # User Name Master User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ 14 P/N YRL-PBINSTL-FUL Rev E PIN Code
Resetting Lock to Factory Default When lock is reset to factory defaults all user codes (including the Master PIN code*) are deleted and all programming features are reset to original default settings (see below). 1. Remove the battery cover and batteries. 2. Remove the interior escutcheon to access the reset button. 3. The reset button (see image at right) is located beside the PCB cable connector. 4. While pressing the reset button (minimum of 3 seconds) reinstall batteries. Release reset button. 5.
Definitions All Code Lockout Mode: This feature is enabled by the Master code. When enabled, it restricts all user (except Master) PIN code access. When attempting to enter a code while the unit is in Lockout, the keypad flashes 8 times and the lock beeps 3 times as well. Audio Mode: Choosing Disable (3) in Audio mode shuts off the code confirmation tone play-back for use in quiet areas. Audio mode is enabled or disabled through feature programming by the Master code.
Feature Programming Through Menu Mode Using Master PIN code* key. 1. Enter the 4-8 digit Master PIN code followed by the 2. Enter digit corresponding to the function to be performed followed by the key. *The Master PIN code must be registered prior to any other programming of the lock.
Programming Troubleshooting Symptom Lock does not respond – door is open and accessible. • • • • Suggested Action Press each keypad button for response when pressed. Check batteries are installed and oriented correctly (polarity) in the battery case. Check batteries are in good condition; replace batteries* if discharged. Check to see if cable is fully connected and not pinched. Lock does not respond – door is locked and inaccessible. • Batteries may be completely discharged.
Hardware Troubleshooting Cycle lock in both the locked and unlocked positions. If problems are found: Bolt will not deadlock a. Check for sufficient clearance of the bolt within the strike-side jamb. Correct this by increasing the depth of the pocket for the bolt. b. Check for misalignment of bolt and/or strike which may be preventing bolt from properly entering the strike. With the door open, extend and retract the bolt; if it is smooth, check the strike alignment.
FCC: Class B Equipment This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
Yale Z-Wave Plus Module Installation and Programming Instructions ® ® ® Installing the Z-Wave Plus Module ® IMPORTANT: the batteries must be removed prior to removing and/or inserting the network module: • Remove battery cover and batteries. • Remove and/or insert Network Module. • Reinstall batteries and battery cover.
! Warning: Changes or modifications to this device, not expressly approved by Yale Security Inc. could void the user's authority to operate the equipment. FCC: Contain FCC ID: U4A-YRHCPZW0FM Model: YRMZW2-US This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Yale ZigBee Module Installation and Programming Instructions ® ® ® Installing the ZigBee® Module IMPORTANT: the batteries must be removed prior to removing and/or inserting the network module: • Remove battery cover. • Remove batteries. • Remove and/or insert network module. • Reinstall batteries. • Replace cover.
FCC: FCC ID: U4A-YRHCPZB0FM Model: YRMZB2 This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
Create Account Step 3 Create a new account, or sign into your existing account if this is not your first Assure Lock with Bluetooth. Once your account has been created, the app will take you through a quick tutorial. Step 6 Lock Settings Tap the lock icon in the bottom left corner to customize the name of your lock, adjust lock settings (e.g. wrong code limits, one-touch locking, operating mode) and view access history.