User Manual

Chapter 4. Basic operation for input channels
53
[Procedure]
1. Use the INPUT block [SEL] switches or the ST IN
block [L]/[R] switches to select the input channel
that you wish to control.
2. In the LCD FUNCTION ACCESS block, press the
INPUT [GATE/COMP] switch several times to
access the following COMP PRM screen.
In the COMP PRM screen you can make compressor
settings for the currently selected input channel.
COMP PRM screen
3. In the upper right of the screen, click the INPUT
COMP LIBRARY button.
The following INPUT COMP LIBRARY popup win-
dow will appear. In this window you can store input
channel compressor settings (input compressor data)
in the library, or recall (load) existing data from the
library.
INPUT COMP LIBRARY popup window
4. From the library list, select data that uses the
desired type.
When you click a row in the library list, that row will
be highlighted, and the compressor type used in that
data and the parameter settings will be displayed in
the edit section.
Hint
Rows numbered 01-34 are displayed as “READ
ONLY, and contain read-only preset data. Initially, it
is a good idea to recall preset data that is close to the
settings you wish, and then modify the parameters as
necessary.
5. Click the RECALL button located in the lower left
of the library list.
The data you selected in step 4 will be recalled into
the input channel you selected in step 1.
You will exit the INPUT COMP LIBRARY popup
window and return to the previous COMP PRM
screen.
Hint
If a ST IN channel or either input channel of a pair is
selected, the same data will be loaded into both chan-
nels.
In the COMP PRM screen, you can also select the
key-in signal (the reference signal that operates the
compressor), and select either LPF or HPF as the fil-
ter that processes the input signal of the compressor.
For details refer to “CS1D Reference Manual (Soft-
ware)” (p.142).
LCD FUNCTION ACCESS
block
INPUT [GATE/COMP] switch
Library list
This list shows the input compressor data that has been
stored in memory. The highlighted row is currently
selected for operations.
Edit section
This shows the settings of the
input compressor data currently
selected in the library list.
These buttons are used for
Store or Recall operations.