ENGLISH PRECAUTIONS PLEASE READ CAREFULLY BEFORE PROCEEDING * Please keep this manual in a safe place for future reference. WARNING Always follow the basic precautions listed below to avoid the possibility of serious injury or even death from electrical shock, short-circuiting, damages, fire or other hazards.
ENGLISH Table of contents About CobraNet™ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 The MY16-C System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Controls & Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Clock Synchronization Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ENGLISH About ■ CobraNet is … An audio networking system developed by Peak Audio (a division of Cirrus Logic, Inc.) that allows real-time transmission and reception of uncompressed digital audio signals via a Fast Ethernet network cable. The network can simultaneously handle up to 64 input and output channels, for a total of 128 channels (64 channels if repeater hubs are used).
Two types of bundle can be used with CobraNet: “multicast” bundles and "unicast" bundles. Multicast bundles can be transmitted from a single device to all devices on the network, while unicast bundles are transferred from a single transmitting device to a single receiving device or a limited number of receiving devices. Unicast bundles are only sent to devices which have been set to the same bundle number as the transmitting device.
On any CobraNet network one device generates a timing signal that all other devices receive and are synchronized to. The device that generates the synchronization signal is known as the “conductor,” while all other devices are “performers.” The conductor for the network is automatically assigned and need not be specified by the operator. When an MY16-C is assigned to be the conductor for the network, the LED indicator to the right of the connector that is connected to the network will light orange.
ENGLISH The MY16-C System The internal signal flow of the MY16-C is shown in the illustration below. 16 audio inputs and 16 audio outputs are available, and for this example channels 1 ~ 8 are bundle 1, and channels 9 ~ 16 are bundle 2.
ENGLISH Controls & Functions ■ Panel Connectors and Switches 3 Gr-LINK Rd-FAULT 4 3 1 PRIMARY 4 Gr-IN USE Or-CONDUCT 2 SECONDARY BUNDLE ASSIGNMENT 4 56 23 4 56 23 4 56 23 4 56 F0 1 4 56 4 56 23 F0 1 F0 1 4 56 4 56 23 F0 1 23 F0 1 23 F0 1 23 F0 1 IN 1 F0 1 CobraNet INTERFACE CARD MODEL MY16-C 6 789 CD AB E IN 2 7 89 CD AB E 7 89 CD AB E OUT 1 7 89 CD AB E OUT 2 7 89 CD AB E 7 89 CD AB E 7 89 CD AB E CD AB E 7 89 MADE IN JAPAN 5 1 [PRIMARY] and 2 [SECONDA
6 BUNDLE ASSIGNMENT [OUT1] and [OUT2] Rotary Switches These switches set the transmit bundle number for audio signals to be transmitted over the CobraNet network. The [OUT1] switches specify the transmit bundle 1 number, and the [OUT2] switches specify the transmit bundle 2 number. Two rotary switches are used to specify each number. See "Bundle Number Setting Procedure" on page 15 for details.
1 2 3 4 5 6 7 8 O N No. Function 1 BIT 2 Fs 3 LATENCY 1 4 LATENCY 2 5 CLOCK 1 6 CLOCK 2 7 RESERVED 1 8 RESERVED 2 n The RESERVED 1 and RESERVED 2 switches are reserved for functions to be implemented in the future. Leave both of these switches OFF. ■ Audio Bits (BIT) DIP switch 1 sets the audio bit depth. BIT Audio Bit Depth OFF 20 bit ON 24 bit ■ Clock Frequency (Fs) DIP switch 2 sets the audio clock frequency or sample rate.
LATENCY 1 LATENCY 2 OFF OFF 5.33 ms OFF ON 2.67 ms ON OFF 1.33 ms ON ON Reserved ENGLISH LATENCY 1/2 DIP switches 3 and 4 (LATENCY 1 and LATENCY 2) set the audio latency. LATENCY n Set all CobraNet devices receiving and transmitting audio signals to the same latency. Clock Synchronization Mode (CLOCK 1/2) DIP switches 5 and 6 (CLOCK 1 and CLOCK 2) specify the clock synchronization mode to be used. See "Clock Synchronization Modes" on page 12 for more information.
ENGLISH Clock Synchronization Modes The MY16-C provides a selection of three clock synchronization modes: Network synchronization, host synchronization 1, and host synchronization 2. Network Synchronization In this mode the MY16-C receives synchronization from the network. This is the normal synchronization mode. When the MY16-C is set to network synchronization, make sure that the audio device in which the MY16-C is installed is synchronized to the MY16-C clock.
MY16-C ENGLISH b. N : Network Synchronization H1 : Host Synchronization 1 N DME64N/24N, PM5D etc Network MY16-C MY16-C H1 DME64N/24N, PM5D etc H1 DME64N/24N, PM5D etc Clock Non-network Device Host Synchronization 2 Use this mode if the MY16-C card is to be synchronized to the clock signal from another MY16-C card installed in the same device.
An example of all three synchronization modes used simultaneously. a. MY16-C N N : Network Synchronization H1 : Host Synchronization 1 H2 : Host Synchronization 2 H2 DME64N/24N, PM5D etc Network MY16-C MY16-C N H1 Clock Non-network Device DME64N/24N, PM5D etc DME64N/24N, PM5D etc b.
ENGLISH MY16-C Card Installation Procedure Carefully read the precautions on page 2 before installing the MY16-C. 1 Set the MY16-C circuit-board DIP switches and rotary switches as required for your application. Refer to "Circuit-board Switches" on page 9 for details about the switch settings. These switches cannot be accessed while the MY16-C card is installed in its host device.
Connecting Two Devices Cross Cable Audio signal and control data MY16-C MY16-C 1 EXT. CLOCK NETWORK 96kHz MID 88.2kHz MASTER 48kHz 2 3 4 2 3 4 5 6 7 8 5 6 7 8 PEAK IN SIGNAL 1 44.1kHz PEAK SCENE NUMBER SIGNAL OUT DME24N DME64N Connecting via a Hub Straight Cable 1 EXT. CLOCK NETWORK 96kHz MID 88.2kHz MASTER 48kHz 2 3 4 2 3 4 5 6 7 8 5 6 7 8 PEAK IN SIGNAL 1 44.
Straight Cable MY16-C DME64N ACU16-C Audio signal and control data Audio signal only Switching Hub Audio signal and control data Audio signal only NETWORK HUB AND BRIDGE LINK LOCK MY16-C 1 EXT. CLOCK NETWORK 96kHz MID 88.2kHz MASTER 2 3 4 5 6 7 8 5 6 7 8 CONDUCT ERROR 88 NHB32-C PEAK 48kHz IN SIGNAL 1 2 3 4 44.1kHz PEAK SCENE NUMBER SIGNAL OUT DME24N n Not compatible with ACU16-C or NHB32-C control signals.
ENGLISH Specifications Digital Input/Output Characteristics Terminal Format Latency DEUTSCH Data Length Audio 20bit 16ch Input / 16ch Output 24bit 14ch Input / 14ch Output 20bit 16ch Input / 16ch Output 24bit 16ch Input / 16ch Output 20bit 16ch Input / 16ch Output 24bit 16ch Input / 16ch Output 5.33ms CobraNet Primary/Secondary CobraNet 2.67ms 1.33ms FRANÇAIS Min. 47.9976 Sampling Frequency Range Typ. 48 Connector RJ45 Max. 48.
ENGLISH specifications.fm Page 19 Monday, April 19, 2004 8:32 PM Straight/Cross Cable Wiring Details Cross Cables Straight Cables DEUTSCH Pins 1 —— 3 2 —— 6 3 —— 1 4 —— 4 5 —— 5 6 —— 2 7 —— 7 8 —— 8 Pins 1 —— 1 2 —— 2 3 —— 3 4 —— 4 5 —— 5 6 —— 6 7 —— 7 8 —— 8 ESPAÑOL 200 FRANÇAIS Dimensions 37 40 120 Unit: mm * Specifications and descriptions in this owner's manual are for information purposes only. Yamaha Corp.
Yamaha Manual Library http://www2.yamaha.co.jp/manual/english/ • This document is printed on chlorine free (ECF) paper with soy ink. • Auf Umweltpapier mit Sojatinte gedruckt. • Ce document a été imprimé sur du papier non blanchi au chlore avec de l'encre d'huile de soja. • Este documento se ha impreso en papel sin cloro alguno, con tinta de soja. U.R.G., Pro Audio & Digital Musical Instrument Division, Yamaha Corporation © 2004 Yamaha Corporation WC95460 404MWCP3.