User Manual

Table Of Contents
Format Details 333
02R96
2
使用说明书
13.4.25 Parameter request (Function call: link)
Reception
This is received if [Parameter change RX] is ON and the [Rx CH] matches
the device number included in the SUB STATUS. This is echoed if [Pa-
rameter change ECHO] is ON.
When this is received, a Parameter Change message will be transmitted on
the [Rx CH].
Refer to the above table for the Functions and Numbers.
13.4.26 Parameter change (Key remote)
Reception
If [Parameter change RX] is ON and the [Rx CH] matches the Device
Number included in the SUB STATUS, these messages are received. If [Pa-
rameter change ECHO] is ON, these messages are echoed.
When this is received, the same processing that is executed when the key
specified by Address is pressed (released).
Transmission
If [Parameter change ECHO] is ON, this message will be retransmitted
without change.
13.4.27 Parameter change (Remote meter)
When transmission is enabled by receiving a Request of Remote meter, the
specified meter information is transmitted every 50 msec for 10 seconds.
When you want to transmit meter information continuously, a Request
must be transmitted continuously within every 10 seconds.
Reception
This is echoed if [Parameter change ECHO] is ON.
Transmission
When transmission has been enabled by a Request, the parameter speci-
fied by Address will be transmitted on the [Rx CH] channel at 50 msec in-
tervals for a duration of 10 seconds.
Transmission will be disabled if the power is turned off and on again, or if
the PORT setting is changed.
If [Parameter change ECHO] is ON, this message will be retransmitted
without change.
13.4.28 Parameter request (Remote meter)
Reception
If [Parameter change RX] is ON and the [Rx CH] matches the Device
Number included in the SUB STATUS, these messages are received. If [Pa-
rameter change ECHO] is ON, these messages are echoed.
When this is received, data of the specified address is transmitted on the
[Rx CH] at intervals of 50 msec as a rule, for a period of 10 seconds.
If Address UL= 0x7F is received, transmission of all meter data will be halt-
ed immediately. (disable)
Transmission
If [Parameter change ECHO] is ON, this message will be retransmitted
without change.
13.4.29 Parameter change (Remote time counter)
When transmission is enabled by receiving a Request of Remote Time
Counter, the Time Counter data is transmitted every 50 msec for 10 sec-
onds. When you want to transmit Counter information continuously, a
Request must be transmitted within every 10 seconds.
Reception
This is echoed if [Parameter change ECHO] is ON.
Transmission
When transmission is enabled by receiving a Request, the Time Counter
information is transmitted on [RxCH] channel every 50 msec for 10 sec-
onds.
Transmission will be disabled if the power is turned off and on again, or if
the PORT setting is changed.
If [Parameter change ECHO] is ON, this message will be retransmitted
without change.
0010ffff 2f
link
0mmmmmmm mh
number High
0mmmmmmm ml
number Low
DATA 0iiiiiii ih
inpatch
0iiiiiii il
0ooooooo oh
outpatch
0ooooooo ol
EOX 11110111 F7
End of exclusive
function number
SCENE LIB LINK 0x20 0-99 (0:response only)
STATUS 11110000 F0
System exclusive message
ID No. 01000011 43
Manufacture's ID number (YAMAHA)
SUB STATUS 0011nnnn 3n
n=0-15 (Device number=MIDI Channel)
GROUP ID 00111110 3E
MODEL ID (digital mixer)
MODEL ID 01111111 7F
Universal
ADDRESS 00010100 14
Function call
0010ffff 2f
link
0mmmmmmm mh
number High
0mmmmmmm ml
number Low
EOX 11110111 F7
End of exclusive
STATUS 11110000 F0
System exclusive message
ID No. 01000011 43
Manufacture's ID number (YAMAHA)
SUB STATUS 0001nnnn 1n
n=0-15 (Device number=MIDI Channel)
GROUP ID 00111110 3E
MODEL ID (digital mixer)
MODEL ID 00001011 0B
02R96
ADDRESS 00100000 20
Key remote
0kkkkkkk kk
Key address H
0kkkkkkk kk
Key address M
0kkkkkkk kk
Key address L
DATA 0ppppppp pp
Release:0, Press:1
EOX 11110111 F7
End of exclusive
STATUS 11110000 F0
System exclusive message
ID No. 01000011 43
Manufacture's ID number (YAMAHA)
SUB STATUS 0001nnnn 1n
n=0-15 (Device number=MIDI Channel)
GROUP ID 00111110 3E
MODEL ID (digital mixer)
MODEL ID 00001011 0B
02R96
ADDRESS 00100001 21
Remote meter
0mmmmmmm mm
ADDRESS UL
0mmmmmmm mm
ADDRESS LU
0mmmmmmm mm
ADDRESS LL
DATA 0ddddddd dd
data1 H
0ddddddd dd
Data1 L
:
:
EOX 11110111 F7
End of exclusive
STATUS 11110000 F0
System exclusive message
ID No. 01000011 43
Manufacture's ID number (YAMAHA)
SUB STATUS 0011nnnn 3n
n=0-15 (Device number=MIDI Channel)
GROUP ID 00111110 3E
MODEL ID (digital mixer)
MODEL ID 00001011 0B
02R96
ADDRESS 00100001 21
Remote meter
0mmmmmmm mm
ADDRESS UL
0mmmmmmm mm
ADDRESS LU
mmmmmmm mm
ADDRESS LL
0ccccccc ch
Count H
0ccccccc cl
Count L
EOX 11110111 F7
End of exclusive
STATUS 11110000 F0
System exclusive message
ID No. 01000011 43
Manufacture's ID number (YAMAHA)
SUB STATUS 0001nnnn 1n
n=0-15 (Device number=MIDI Channel)
GROUP ID 00111110 3E
MODEL ID (digital mixer)
MODEL ID 00001011 0B
02R96
ADDRESS 00100010 22
Remote Time counter
0000tttt 0t
0:Time code, 1:Measure.Beat.Clock
0ddddddd dd
Hour / Measure H
0ddddddd dd
Minute / Measure L
DATA 0ddddddd dd
Second / Beat
0ddddddd dd
Frame / Clock
EOX 11110111 F7
End of exclusive