Operation Manual

RECORDING-SETUP
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● A5000/A4000 • Chapter 6 RECORD Mode 157
Process
[REC] Button [F2] Button Knob 1 to select
"REC-Process"
Use this page to select whether the A5000/A4000 normalizes
samples immediately after recording them.
Knob 1
[ Turn] Page
Selects display pages.
[ Press] Tree View
Calls the Tree View display (page 83).
Knob 2
[ Press] MONITOR
Pressing this knob alternately turns the MONITOR func-
tion on and off. A speaker icon appears above Knob 2
when the MONITOR function is turned on.
Knob 3
[ Turn] Auto Normalize
Set this on if you want the A5000/A4000 to normalize
each new sample immediately after recording it.
If you select on, the A5000/A4000 automatically adjusts
the recorded waveform by proportionately raising all lev-
els such that the highest level comes to just below the clip
point, as illustrated below. (The clip point is the maxi-
mum level appropriate for digital processing.)
[Range] off, on
Since normalization will occur automatically when
recording ends, some time may be required for pro-
cessing.
Knob 1 Knob 2 Knob 3 Knob 4 Knob 5
Turn
action
Page
Auto
Normalize
——
Press
action
Tree View MONITOR ———
Recorded sample
Normalize