About the COMMANDS
226 Chapter 9 COMMAND • A5000/A4000 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
MOVE
[COMMAND/EXIT] Button Knob 1 to highlight display line 4
Press Knob 2
Moves the samples assigned to a program to a sample bank,
or the samples in a sample bank to another sample bank or
program.
This command can be used to combine two sample banks into one,
or consolidate all the samples in a program that was created with-
out using sample banks into a sample bank, etc.
[Operation]
1. Select the Move Type.
2. Select the program or sample bank to be moved.
3. Select the destination program or sample bank.
4. Press Knob 1 (EXEC) or Knob 5 (EXEC&CONT), and the move
conrmation display will appear. Press Knob 5 (YES) to execute
the move operation.
If Knob 1 (EXEC) is used to execute the command, the display pre-
vious to the command menu will be recalled after execution has fin-
ished. If Knob 5 (EXEC&CONT) is used to execute the command,
the move display will be retained so you can continue and perform
further move operations.
Knob 1
[ Turn] Cursor
Positions the cursor.
[ Press] EXEC
Press this knob to call the move conrmation display.
Press Knob 5 (YES) to actually execute the move opera-
tion.
Knob 4
[ Turn] Move Type
Species what type of data is to be moved to what type of
destination, and how Easy Edit parameters are to be han-
dled.
[Range] ProgramSampleBank,
Program(Freeze)
SampleBank,
SampleBank
Program,
SampleBank(Freeze)
Program,
SampleBank
SampleBank
Program
SampleBank ... All samples assigned
to the selected program (not including sample
banks or samples contained in sample banks)
are moved to the selected sample bank.
Program(Freeze)
SampleBank ... After applying
the Easy Edit parameters to the samples
(Freeze page 213), all samples assigned to
the selected program (not including sample
banks or samples contained in sample banks)
are moved to the selected sample bank.
SampleBank
Program ... All samples contained
in the selected sample bank are removed from
the sample bank and assigned to the selected
program.
SampleBank(Freeze)
Program ... After applying
the sample bank parameters to the samples it
contains (Freeze page 213), all samples
contained in the selected sample bank are
removed from the sample bank and assigned
to the selected program.
SampleBank
SampleBank ... All samples con-
tained in the selected sample bank are moved
to a second selected sample bank.
Knob 5
[ Press] EXEC&CONT
Press this knob to call the move conrmation display.
Press Knob 5 (YES) to actually execute the move opera-
tion.
Knob 1
Same function as Cursor q (page 226).
Knob 2
[ Turn] From Program
Species the source program from which samples are to
be moved. This parameter can be used when the Move
Type is set to ProgramSampleBank or Pro-
gram(Freeze)SampleBank.
[Range] 001 128
Cursor q
Knob 1 Knob 2 Knob 3 Knob 4 Knob 5
Turn
action
Cursor ——Move Type
Press
action
EXEC ———EXEC&CONT
q
Cursor
Cursor w
Knob 1 Knob 2 Knob 3 Knob 4 Knob 5
Turn
action
Cursor From Program
From
SampleBank
To Program
To
SampleBank
Press
action
EXEC ———EXEC&CONT
w
Cursor