Operation Manual
About the COMMANDS
226 Chapter 9 COMMAND • A5000/A4000 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
MOVE
[COMMAND/EXIT] Button → Knob 1 to highlight display line 4
→ Press Knob 2
Moves the samples assigned to a program to a sample bank,
or the samples in a sample bank to another sample bank or
program.
• This command can be used to combine two sample banks into one,
or consolidate all the samples in a program that was created with-
out using sample banks into a sample bank, etc.
[Operation]
1. Select the Move Type.
2. Select the program or sample bank to be moved.
3. Select the destination program or sample bank.
4. Press Knob 1 (EXEC) or Knob 5 (EXEC&CONT), and the move
confirmation display will appear. Press Knob 5 (YES) to execute
the move operation.
• If Knob 1 (EXEC) is used to execute the command, the display pre-
vious to the command menu will be recalled after execution has fin-
ished. If Knob 5 (EXEC&CONT) is used to execute the command,
the move display will be retained so you can continue and perform
further move operations.
Knob 1
[ Turn] Cursor
Positions the cursor.
[ Press] EXEC
Press this knob to call the move confirmation display.
Press Knob 5 (YES) to actually execute the move opera-
tion.
Knob 4
[ Turn] Move Type
Specifies what type of data is to be moved to what type of
destination, and how Easy Edit parameters are to be han-
dled.
[Range] Program→SampleBank,
Program(Freeze)
→SampleBank,
SampleBank
→Program,
SampleBank(Freeze)
→Program,
SampleBank
→SampleBank
• Program
→SampleBank ... All samples assigned
to the selected program (not including sample
banks or samples contained in sample banks)
are moved to the selected sample bank.
• Program(Freeze)
→SampleBank ... After applying
the Easy Edit parameters to the samples
(Freeze — page 213), all samples assigned to
the selected program (not including sample
banks or samples contained in sample banks)
are moved to the selected sample bank.
• SampleBank
→Program ... All samples contained
in the selected sample bank are removed from
the sample bank and assigned to the selected
program.
• SampleBank(Freeze)
→Program ... After applying
the sample bank parameters to the samples it
contains (Freeze — page 213), all samples
contained in the selected sample bank are
removed from the sample bank and assigned
to the selected program.
• SampleBank
→SampleBank ... All samples con-
tained in the selected sample bank are moved
to a second selected sample bank.
Knob 5
[ Press] EXEC&CONT
Press this knob to call the move confirmation display.
Press Knob 5 (YES) to actually execute the move opera-
tion.
Knob 1
Same function as Cursor q (page 226).
Knob 2
[ Turn] From Program
Specifies the source program from which samples are to
be moved. This parameter can be used when the Move
Type is set to Program→SampleBank or Pro-
gram(Freeze)→SampleBank.
[Range] 001 — 128
Cursor q
Knob 1 Knob 2 Knob 3 Knob 4 Knob 5
Turn
action
Cursor ——Move Type —
Press
action
EXEC ———EXEC&CONT
q
Cursor
Cursor w
Knob 1 Knob 2 Knob 3 Knob 4 Knob 5
Turn
action
Cursor From Program
From
SampleBank
To Program
To
SampleBank
Press
action
EXEC ———EXEC&CONT
w
Cursor