Owner`s manual

CHANNEL SETUP unit
5 CTRL RESET
Determines whether the control value is reset or maintained for each MIDI channel when
the program is switched by a program change message or other mean. Select ON to reset
or NO to maintain. MIDI channels B01 through B16 are not available on the A4000.
6 NOTE ON TYPE
Selects the type of playback which will occur when note-on messages are received for
each MIDI channel. MIDI channels B01 through B16 are not available on the A4000.
PROGRAM LFO unit
7 WAVE
Selects the PROGRAM LFO waveform. The selected waveform is used to modulate the
sound in synchronization with the received MIDI clock and the playback tempo.
8 CYCLE
Selects the note type corresponding to the one PROGRAM LFO cycle.
9 INIT PHASE
Selects the initial phase of the PROGRAM LFO.
) SYNC
Selects the PROGRAM LFO synchronization method. MANUAL allows the PROGRAM LFO
to be synchronized to the specified tempo, and MIDI allows the PROGRAM LFO to be
synchronized to a received MIDI clock.
! TEMPO
Sets the tempo for MANUAL synchronization. This has no effect when MIDI synchronization
is selected.
@ RESET CH
Specifies the MIDI channel via which a received note-on message will initialize the phase
of the PROGRAM LFO when MANUAL synchronization is selected. This has no effect when
MIDI synchronization is selected.
# NOTE
Specifies the note number which will initialize the phase of PROGRAM LFO. This has no
effect when MIDI synchronization is selected.
$ VALUE
Sets the values for STEP 1 through 16 of the step wave waveform. This has no effect on
waves other than the step wave.
% SLOPE
Selects the method by which the step wave steps will be smoothly connected. This has no
effect on waves other than the step wave.
^ TOTAL STEPS
Sets the total number of steps for the step wave. Values for steps beyond the total step
number have no effect.
12