Specifications

RX-V550/HTR-5750
RX-V450/HTR-5740/DSP-AX450
24
RX-V550/HTR-5750
RX-V450/HTR-5740/DSP-AX450
Cause: The voltage in the power supply section is
abnormal.
Supplementary information: The abnormal voltage is
displayed in % based on 5V as 100%.
Turning on the power without correcting the abnormality
will cause the protection function to work 1 second later
and the power supply will be shut off.
When there is a history of protection
function due to an abnormal voltage in
the power supply section
電源部の電圧異常によるプロテク
ション履歴がある場合
Version (1 alphabet)
バージョン(英1文字)
Voltage display in %
電圧の%表示
原因: 電源部の電圧が異常。
補足 異常時の電圧の状態を、5V100%とした値で%表示し
ます。
異常状態のままパワーオンすると、1秒後にプロテクションがか
かり、電源が切れます。
Opening message / 
オープニング表示
DIAG menu display / 
ダイアグメニュー表示
After a few seconds
数秒後
Version (1 alphabet)
バージョン(英1文字)
When there is no history
of protection function
プロテクション履歴がない場合
When there is a history of protection function:
When there is a history of protection
function due to excess current
過電流によるプロテクション
履歴がある場合
Version (1 alphabet)
バージョン(英1文字)
プロテクション履歴がある場合:
Display provided when DIAG started
The FL display of the main unit displays the protection
function history data and the version (1 alphabet) and the
DIAG menu [sub-menu (YSS MARGIN) of DIAG menu
No.1 DSP THROUGH] a few seconds later.
When there is no history of protection function:
● ダイアグ起動時の表示
本体のFLディスプレイにプロテクション履歴情報とバージョン
(英1文字)が表示され、数秒後にダイアグメニュー(No.1 DSP
THROUGHのサブメニューYSS MARGIN)になります。
プロテクション履歴がない場合:
Cause: An excessive current flowed through the power
amplifier.
Supplementary information: As current of the power
transistor is detected, the abnormal channel can be
identified by checking the current detect transistor.
Turning on the power without correcting the abnormality
will cause the protection function to work immediately and
the power supply will instantly be shut off.
Note)
Applying the power to a unit without correcting the
abnormality can be dangerous and cause additional
circuit damage.
The output transistors in each amplifier channel
should be checked for damage before applying any
power.
Amplifier current should be monitored by measuring
across the emitter resistors for each channel.
原因: パワーアンプに過電流が流れた。
補足 パワートランジスタの電流を検出していますので、電流検
出トランジスタをチェックすれば異常チャンネルが特定で
きます。
異常状態のままパワーオンすると、瞬時にプロテクションがかか
り、すぐに電源が切れます。