User Manual

Operation when changing NETWORK settings
(Reference Manual, p. 191)
After changing settings in the NETWORK popup window, which is accessed by pressing the SETUP button in
the Function Access Area, then pressing the NETWORK button, the CL series must be restarted.
NOTE
The NETWORK setting is not changed, even if the CL series is initialized.
Operation when changing settings in the DANTE SETUP popup window
(Reference Manual, p. 198)
When settings have been changed in the DANTE SETUP popup window, the ACCESS indicator lights while
the setting changes are stored on the unit.
The ACCESS indicator lights when settings for the following are changed.
- Parameters in the DANTE SETUP screen
- Parameters in the WORD CLOCK screen
- Patch settings, Library operations, and AUTO SETUP button operations in the DANTE INPUT PATCH
popup window
- Parameters in the OUTPUT tab of the I/O RACK screen
In order to apply changes to settings in the DANTE SETUP popup window, the unit must be turned off, then
on again; however, turn the unit off after the ACCESS indicator turns off.
If the SECONDARY PORT setting or the IDs for the CL series or the I/O rack in the DANTE SETUP popup
window has been changed, the units must be turned off, then on again. Follow the steps below to perform the
operation.
NOTE
The SECONDARY PORT and CONSOLE ID settings are not changed, even if the CL series is initialized.
Changing the SECONDARY PORT setting
1. Unplug th
e Ethernet cable from the Dante connectors on the CL series and I/O rack.
NOTE
When changing the SECONDARY PORT setting, the network topology for the CL series and I/O rack
must also be changed. For example, if the setting is changed to DAISY CHAIN while leaving the
connection for the REDUNDANT setting, it will no longer be possible to transmit audio. Before changing
the setting, first disconnect the cables.
2. Confirm the SECONDARY PORT setting for the CL series and the DIP switch setting on the I/O
rack.
3. Turn the CL series and I/O rack off, then on again.