User Manual

Table Of Contents
Channel Job
Reference Manual
73
NOTE
The [SEL] key of the channel set for Mute Safe will light, and the on-screen fader for that channel
will be highlighted in green. You can cancel the Mute Safe status by pressing a lit [SEL] key once
again to make it go dark.
Using the temporary unmute function
If one of the mute group master buttons on a channel is ON, press the [ON] key for that
channel to temporarily unmute the channel. However, in PREVIEW mode, any operation
during mute with pressing of the [ON] key is disabled.
Using the Recall Safe function
“Recall Safe” is a function that excludes only specific parameters/channels (DCA groups) from
Recall operations. Unlike the Focus Recall function (page 94), which you can apply to
individual scenes, the Recall Safe settings are globally applied to all scenes.
NOTE
Simply selecting a parameter in step 4 does not enable Recall Safe. To turn Recall Safe on or off,
you must also perform the operation described in step 5.
Channel Link (page 76) and bus settings are not subject to Recall Safe; they will always be
reproduced in the recalled scene.
This means that if Recall Safe is enabled for one of several channels included in a link group or
one of two channels set to stereo, the parameter settings of that channel may differ from those of
the other channel(s). In such cases, the applicable parameter will be automatically re-linked the
next time it is operated.
You can globally apply Recall Safe to channel links by using the global parameter.
You can use the Recall Safe function along with the Focus Recall function (
page 94). Channels
or parameters that are excluded from Recall operations by either Focus or Recall Safe will not be
recalled.
If you perform a Recall operation while holding down a [SEL] key, the Recall Safe settings for the
corresponding channel will temporarily be enabled for that Recall operation.
STEP
1. In the Function Access Area, press the CH JOB button.
2. Press the RECALL SAFE button in the CH JOB menu.
3. Press the [SEL] key for the channel or DCA group that will be affected by Recall Safe
operations.
4. Use the Safe Parameter select button in the RECALL SAFE MODE window to select
the target for Recall Safe operations.
5. To enable Recall Safe for the selected channel, turn the SAFE button on. (If you
selected a DCA group, turn on either the LEVEL/ON button or the ALL button.)
6. To enable Recall Safe for global parameters, turn on the buttons of the GLOBAL
RECALL SAFE field.
7. When you have finished making settings, press the CLOSE button to close the
window. Then perform a Recall operation.
DCA/MUTE GROUP ASSIGN
MODE window
CH JOB
menu
Function
Access Area
CH JOB
menu