User Manual
Table Of Contents
- How to Use This Reference Manual
- Contents
- Function Tree
- SELECTED CHANNEL section
- Centralogic section
- Input and output patching
- Input channels
- Signal flow for input channels
- Specifying the channel name/icon
- HA (head amp) settings
- Sending the signal from an input channel to the STEREO/MONO bus
- Added pan function (Monaural input channels only)
- Sending a signal from an input channel to a MIX/ MATRIX bus
- Channel name display indication
- Correcting delay between channels (Input Delay)
- Surround output for input channels
- Channel library operations
- OUTPUT channels
- EQ and Dynamics
- Channel Job
- Scene memory
- Monitor and Cue functions
- Talkback and Oscillator
- Meters
- Graphic EQ, Parametric EQ, Effects, and PREMIUM RACK
- I/O devices and external head amps
- MIDI
- Recorder
- Setup
- About the SETUP screen
- User settings
- Preferences
- USER DEFINED keys
- Functions that can be assigned to USER DEFINED keys
- USER DEFINED knobs
- Functions that can be assigned to USER DEFINED knobs
- Assignable encoders
- Functions that can be assigned to the assignable encoders
- GAIN/PAN/ASSIGN knob (assignable encoder) functions
- Custom fader bank
- Master fader
- Custom fader bank functions
- Console Lock
- Saving and loading setup data to and from a USB flash drive
- Formatting a USB flash drive
- Word clock and slot settings
- Using cascade connections
- Basic settings for MIX buses and MATRIX buses
- Switching the entire phantom power supply on/off
- Specifying the brightness of the touch screen, LEDs, channel name displays, and lamps
- Setting the date and time of the internal clock
- Setting the network address
- Dante audio network settings
- Dante Device Lock
- Support for Dante Domain Manager
- Using GPI (General Purpose Interface)
- Help function
- Other functions
- Initializing the unit to factory default settings
- Adjusting the detection point of the touch screen (Calibration function)
- Adjusting the faders (Calibration function)
- Fine-tuning the input and output gain (Calibration function)
- Adjusting the channel color (Calibration function)
- Adjusting the brightness of the channel name display
- Adjusting the contrast of the channel name display
- Initializing the console settings and Dante audio network settings
- Update procedure for NAME SUB CPU firmware
- Update function to Dante firmware
- Warning/Error Messages
- Index
- Data List
- EQ Library List
- DYNAMICS Library List
- Dynamics Parameters
- Effect Type List
- Effects Parameters
- Premium Rack Processor Parameters
- Parameters That Can Be Assigned to Control Changes
- NRPN Parameter Assignments
- Mixing Parameter Operation Applicability
- MIDI Data Format
- Input/Output Characteristics
- Electrical Characteristics
- Mixer Basic Parameters
- Pin Assignment
- MIDI Implementation Chart
Monitor and Cue functions
V5 Reference Manual
117
MONITOR FADER field
0
MONITOR FADER LEVEL knob
Indicates the monitor level. Press this knob to adjust the monitor level using the
multifunction knob. Or, press the Centralogic section bank select [STEREO] key, and
then use the monitor fader to adjust the level.
A FADER ASSIGN indicator
Indicates the fader(s) to which the monitor level is assigned. Indicator assignments are
as follows:
MONITOR DELAY field
This field enables you to specify the monitor delay setting by which the monitor out signal is
delayed.
B AUTO BYPASS button
Turn this on to automatically bypass monitor delay when the cue is on.
C MONITOR DELAY knob
Indicates the currently-specified delay time. The millisecond value is indicated above the
knob, and the delay time value in currently-selected units and the currently-selected
scale type are indicated below the knob. However, if the scale is set to ms, the delay time
value is not shown above the knob.
Press this knob to control the level using the multifunction knobs.
Meter field
Indicates the monitor output level.
D Meters
This field indicates the output level of the monitor L/R/C channels.
E MONITOR OUT PATCH button
Press this button to open the PORT SELECT window, in which you can select an output
port to patch to the monitor out L/R/C channels.
NOTE
• You can specify output ports only for MONITOR OUT L and R, and monitor through two speakers.
• If you have not specified an output port for MONITOR OUT C, selecting the MONO (C) button or
LCR button as the monitor source will automatically cause the MONO channel signal to be
distributed to MONITOR OUT L/R.
F ASSIGN field
If you have selected DEFINE in the SOURCE SELECT field, you can use the ASSIGN field
to specify multiple monitor sources. The following table shows the monitor sources that
you can select in the ASSIGN field.
NOTE
You can select a maximum of eight monitor sources in the ASSIGN field. If you select eight
monitor sources, no further selections will be possible. Turn off the buttons of unneeded sources.
MASTER A MASTER A fader only
MASTER A+ MASTER A, as well as MASTER B fader and Custom fader bank
MASTER B MASTER B fader only
MASTER B+ MASTER B, as well as Custom fader bank
CUSTOM One of the Custom fader bank faders
CUSTOMs Multiple Custom fader bank faders
DANTE 1-64 Output channels 1-64 to audio network
OMNI1-8 OMNI OUT jacks 1-8
DIGI OUT L/R DIGITAL OUT jack on the CL unit
SLOT1-1 - SLOT3-16 Output channels 1-16 of an I/O card installed in slots 1-3
MIX 1-24 Output signals of MIX channels 1-24
MTRX 1-8 MATRIX buses 1 - 8 output signals
STEREO STEREO L/R channel output signals
MONO (C) MONO channel output signal
OMNI 1-2 - OMNI 7-8
OMNI IN jacks 1 - 8 input signals (per two
channels)
PB OUT Recorder’s PLAYBACK OUT signals