If the green indicator is blinking, the unit is operating as the word clock master.
If the green indicator lights, the unit is operating as a word clock slave and synching to the
word clock.
Information messages
The indicators will remain lit /blinking cyclically to report the status.
If the orange [SYNC] indicator is not lit, the unit is operating correctly.
If the green [SYNC] indicator is not lit, the device’s word clock is not defined.
[SYNC] indicators Meaning Possible solution
A non-GbE-compatible device
is connected.
If audio is transmitted over the
Dante network, use a GbE-
compatible device.
The SECONDARY connector
has taken over
communications during
redundant network operation.
Check the circuit connected to the
PRIMARY connector.
An abnormality has occurred
on the circuit connected to the
SECONDARY connector
during redundant network
operation.
Check the circuit connected to the
SECONDARY connector.
Lit
Lit or
blinking
Blinking
Lit or
blinking
Flash x2
Lit or
blinking
[SYNC] indicators Meaning Possible solution
Syncing the Dante network
Please wait until started has
completed or until the unit has
finished synchronization. It may
take up to 45 seconds for
completion.
Waiting to receive setting data
Use REMOTE HA ASSIGN in the
system to sync with a console or
R Remote set to “WITH RECALL.
For an R series console with the
START UP MODE set to
REFRESH, after startup both
input and output are muted until
the setting data is received.
For a single R series console, do
not set “WITH RECALL” from
multiple consoles.
The device is operating
correctly as a word clock
master.
This indicates that the device is
operating as a word clock master.
The device is operating
correctly as a word clock
slave.
This indicates that the device is
operating as a word clock slave
and synching to the word clock.
Lit
Blinking
Lit