User Manual

Table Of Contents
Setup
V5 Reference Manual
272
3 GPI IN SETUP button
The button shows the name of the currently-selected function or parameter. Press this
button to display the GPI IN SETUP window.
NOTE
The items that can be selected in the GPI IN SETUP window are the same as for the USER
DEFINED keys (page 224).
4 Switch attribute select button
This button selects the switch attribute. Each time you press the button, its indication
will alternate between LATCH and UNLATCH.
................. LATCH (a switch that alternately turns on/off each time it is pressed)
is selected.
................. UNLATCH (a switch that is on only while pressed and is off when
released) is selected.
Using GPI OUT
The GPI OUT ports of the GPI OUT connector allow you to control an external device by
performing operations on the CL series console.
STEP
1. Connect an external device to the CL series console’s GPI connector.
2. In the Function Access Area, press the SETUP button.
3. In the SETUP screen, press the MIDI/GPI button.
4. In the MIDI/GPI screen, press the GPI tab.
5. Specify the POLARITY MODE for each port as appropriate for the specifications of
the external device you’re using.
6. To assign a function or parameter that you want to control, press the GPI OUT
SETUP button.
7. In each field of the GPI OUT SETUP window, select the desired function and
parameter, then press the OK button.
SETUP screen MIDI/GPI screen