User Manual

CL/QL External Surround Metering Guide
www.yamahaproaudio.com
6
In the left column of the CH SELECT screen, which has now appeared, select
ST/MONO MONI/CUE. Then the various Surround Monitor outputs will be shown on
the screen. For this first output,
select MMTX L. This is the
Monitor Matrix Left output. The
signal is taken from the Monitor
Matrix (Downmix) output, and is
not affected by the Monitor Level
adjustment. So the metering is
independent of listening level.
Press the “+” button at the top of
the window, to access the next
output. Assign MMTX R.
Continue until all 6 MMTX
outputs are assigned to the Slot
outputs 1-6:
3.4 CL/QL USER DEFINED KEYS & GPI
Firmware version 3 introduces layers for the console User Defined Keys, so more
functions can be accessed from these buttons. They can be used to send GPI triggers
to the RTW TM7, which can change the
metering view, or start/stop certain
features.
Firstly, access the SETUP menu, and
select the USER SETUP.
Then select the USER DEFINED KEYS page. By default BANK A already has functions
assigned, but Banks B, C and D are all blank. So BANK B is selected in this example.
Press button #1 to assign a function.