Star Network
In a star network, each device is connected to a central
GbE-compatible network switch. This connection
enables you to configure a wide-band, large-scale
network.
Settings
Turn on Dante DIP switch 1 (DOWN).
If there are multiple Dante-compatible devices from
Yamaha that require an ID setting connected to the
same network, set a different ID for each device. Make
sure to change the settings of the rotary switch while
the power to the unit is turned off; otherwise, the ID
setting will not be effective.
NOTE
We recommend a network switch that features various
functions for controlling and monitoring the network (such as
QoS).
Do not use the EEE functionality of network switches.
Star Network (Redundant Network)
You can set up a star network redundant so that there is
no audio loss even if interference occurs on the network.
A redundant network consists of two circuits, a primary
circuit and a secondary circuit. Normally, the network
operates on the primary circuit. However, if the primary
connection is broken, the secondary circuit will
automatically take over communications.
Settings
Turn on Dante DIP switch 1 (DOWN).
If there are multiple Dante-compatible devices from
Yamaha that require an ID setting connected to the
same network, set a different ID for each device. Make
sure to change the settings of the rotary switch while
the power to the unit is turned off; otherwise, the ID
setting will not be effective.
NOTE
We recommend a network switch that features various
functions for controlling and monitoring the network (such as
QoS).
Do not use the EEE functionality of network switches.
The Dante [SYNC] indicator flashes as follows when
communication error occurs on the Dante Redundant
Network.
Connecting MADI-compatible
Devices
You can connect the RMio64-D to MADI-compatible
devices using either 75Ω coaxial (BNC) or optical (SC)
cables.
Using 75Ω Coaxial Cables
NOTE
Coaxial cables of up to 100 meters (theoretical value) can be
used.
Error on a primary network
Error on a secondary network
Light or
flash
(green)
Flashes
once
(orange)
Light or
flash
(green)
Flashes
twice
(orange)
Computer
Network switch A
Network switch B
Primary Dante
Secondary Dante
CL5
Rio3224-D (ID#1)
RMio64-D (ID#2)
MADI-compatible device
RMio64-D
COAXIAL
OUT
COAXIAL
IN
COAXIAL
OUT
COAXIAL