User Manual
Table Of Contents
- How to Use This Reference Manual
- Contents
- Function Tree
- SELECTED CHANNEL section
- Centralogic section
- Input and output patching
- Input channels
- Signal flow for input channels
- Specifying the channel name/icon
- HA (head amp) settings
- Sending the signal from an input channel to the STEREO/MONO bus
- Added pan function (Monaural input channels only)
- Sending a signal from an input channel to a MIX/ MATRIX bus
- Channel name display indication
- Correcting delay between channels (Input Delay)
- Surround output for input channels
- Channel library operations
- OUTPUT channels
- EQ and Dynamics
- Channel Job
- Scene memory
- Monitor and Cue functions
- Talkback and Oscillator
- Meters
- Graphic EQ, Parametric EQ, Effects, and PREMIUM RACK
- I/O devices and external head amps
- MIDI
- Recorder
- Setup
- About the SETUP screen
- User settings
- Preferences
- USER DEFINED keys
- Functions that can be assigned to USER DEFINED keys
- USER DEFINED knobs
- Functions that can be assigned to USER DEFINED knobs
- Assignable encoders
- Functions that can be assigned to the assignable encoders
- GAIN/PAN/ASSIGN knob (assignable encoder) functions
- Custom fader bank
- Master fader
- Custom fader bank functions
- Console Lock
- Saving and loading setup data to and from a USB flash drive
- Formatting a USB flash drive
- Word clock and slot settings
- Using cascade connections
- Basic settings for MIX buses and MATRIX buses
- Switching the entire phantom power supply on/off
- Specifying the brightness of the touch screen, LEDs, channel name displays, and lamps
- Setting the date and time of the internal clock
- Setting the network address
- Dante audio network settings
- Dante Device Lock
- Support for Dante Domain Manager
- Using GPI (General Purpose Interface)
- Help function
- Other functions
- Initializing the unit to factory default settings
- Adjusting the detection point of the touch screen (Calibration function)
- Adjusting the faders (Calibration function)
- Fine-tuning the input and output gain (Calibration function)
- Adjusting the channel color (Calibration function)
- Adjusting the brightness of the channel name display
- Adjusting the contrast of the channel name display
- Initializing the console settings and Dante audio network settings
- Update procedure for NAME SUB CPU firmware
- Update function to Dante firmware
- Warning/Error Messages
- Index
- Data List
- EQ Library List
- DYNAMICS Library List
- Dynamics Parameters
- Effect Type List
- Effects Parameters
- Premium Rack Processor Parameters
- Parameters That Can Be Assigned to Control Changes
- NRPN Parameter Assignments
- Mixing Parameter Operation Applicability
- MIDI Data Format
- Input/Output Characteristics
- Electrical Characteristics
- Mixer Basic Parameters
- Pin Assignment
- MIDI Implementation Chart
I/O devices and external head amps
V5 Reference Manual
174
DANTE INPUT PATCH window
Displayed when you press the DANTE INPUT PATCH button in the I/O DEVICE screen
(DANTE PATCH page). Specify the 64 channels that will be input from the I/O devices to the
console.
1 LIBRARY button
Enables you to store or recall the DANTE INPUT PATCH settings to or from the library.
You can store ten sets of settings in the library.
NOTE
• If you recall data whose I/O device registration state differs from the current state, patching to
devices not registered in the I/O device list will be kept in its current state, and will not be
recalled. (The settings are recalled for an R unit, or an external CL series console.)
• Similarly, if the UNIT ID is different than when the data was stored, the settings will not be
recalled; the current state will be maintained.
2 AUTO SETUP button
The current I/O device connection status will be ascertained, and input patching to the
console will be performed automatically according to the order in which they are
registered in the I/O device list.
When you press this button, a confirmation popup dialog will appear, asking you to
confirm the execution of auto patching. Press the OK button to execute auto patching.
Otherwise, press CANCEL to return to the previous screen.
3 Port select buttons
Press this button to open the PORT SELECT window.
“Dante Device ID number (hexadecimal) and channel number
(decimal)” are shown in the upper row on the button.
The first eight characters of the channel label (Dante Audio Channel
Label) for each port are shown in the lower row on the button.
When a patch establishes an audio connection via AES67, “AES67” is displayed on the
port selection buttons, etc.
If no patch has been assigned, the upper row will indicate“---” and the lower row will
indicate nothing.
NOTE
• If you’ve connected a device other than an I/O device supported by the CL series, the upper
line of the button will show the first four letters of the Device Label, a dash “-” , and the channel
number (decimal).
• If a CL series console is mounted, the display for the upper row of buttons will be “CL#X” (where
X is the ID number of the mounted CL unit).
• If no Dante Audio Channel Label has been specified, a value equal to the channel number will
be displayed in the lower row.
• You can set the Dante Audio Channel Label using Audinate “Dante Controller” software. For the
latest information, refer to the Yamaha pro audio website.
https://www.yamaha.com/proaudio/
• The Audinate “Dante Controller” software is required to use the CL console in AES67 mode.
Routing via AES67 is possible only by using Dante Controller.
• Channels with patches that use AES67 offline will synchronize with the patch settings that are
saved on the target device when connected with the device.
1 2
3