User Manual
Table Of Contents
- How to Use This Reference Manual
- Contents
- Function Tree
- SELECTED CHANNEL section
- Centralogic section
- Input and output patching
- Input channels
- Signal flow for input channels
- Specifying the channel name/icon
- HA (head amp) settings
- Sending the signal from an input channel to the STEREO/MONO bus
- Added pan function (Monaural input channels only)
- Sending a signal from an input channel to a MIX/ MATRIX bus
- Channel name display indication
- Correcting delay between channels (Input Delay)
- Surround output for input channels
- Channel library operations
- OUTPUT channels
- EQ and Dynamics
- Channel Job
- Scene memory
- Monitor and Cue functions
- Talkback and Oscillator
- Meters
- Graphic EQ, Parametric EQ, Effects, and PREMIUM RACK
- I/O devices and external head amps
- MIDI
- Recorder
- Setup
- About the SETUP screen
- User settings
- Preferences
- USER DEFINED keys
- Functions that can be assigned to USER DEFINED keys
- USER DEFINED knobs
- Functions that can be assigned to USER DEFINED knobs
- Assignable encoders
- Functions that can be assigned to the assignable encoders
- GAIN/PAN/ASSIGN knob (assignable encoder) functions
- Custom fader bank
- Master fader
- Custom fader bank functions
- Console Lock
- Saving and loading setup data to and from a USB flash drive
- Formatting a USB flash drive
- Word clock and slot settings
- Using cascade connections
- Basic settings for MIX buses and MATRIX buses
- Switching the entire phantom power supply on/off
- Specifying the brightness of the touch screen, LEDs, channel name displays, and lamps
- Setting the date and time of the internal clock
- Setting the network address
- Dante audio network settings
- Dante Device Lock
- Support for Dante Domain Manager
- Using GPI (General Purpose Interface)
- Help function
- Other functions
- Initializing the unit to factory default settings
- Adjusting the detection point of the touch screen (Calibration function)
- Adjusting the faders (Calibration function)
- Fine-tuning the input and output gain (Calibration function)
- Adjusting the channel color (Calibration function)
- Adjusting the brightness of the channel name display
- Adjusting the contrast of the channel name display
- Initializing the console settings and Dante audio network settings
- Update procedure for NAME SUB CPU firmware
- Update function to Dante firmware
- Warning/Error Messages
- Index
- Data List
- EQ Library List
- DYNAMICS Library List
- Dynamics Parameters
- Effect Type List
- Effects Parameters
- Premium Rack Processor Parameters
- Parameters That Can Be Assigned to Control Changes
- NRPN Parameter Assignments
- Mixing Parameter Operation Applicability
- MIDI Data Format
- Input/Output Characteristics
- Electrical Characteristics
- Mixer Basic Parameters
- Pin Assignment
- MIDI Implementation Chart
MIDI
V5 Reference Manual
196
• Single mode (when the SINGLE button is on):
Only Program Changes of the transmit (Tx) and receive (Rx) channels specified in the
MIDI SETUP page will be transmitted and received. When a program change on the Rx
channel is received, the event assigned to that program number of the corresponding
channel in the list will be executed.
When you execute the specified event on the CL series console, the Program Change of
the corresponding program number will be transmitted on the Tx channel shown in the
list. (If an event is assigned to more than one program number on the same channel,
the lowest-numbered program number will be transmitted.)
• When the OMNI button is on in SINGLE mode:
Program changes of all MIDI channels will be received. However, regardless of the MIDI
channel that is received, the event assigned to the corresponding program number of
the Rx channel will be executed. Turning on the OMNI button will not change the
operation for Program Change transmission.
• When the BANK button is on in SINGLE mode
The CH indication in the list will change to BANK (bank number), and Bank Select
(Control Change #0, #32) and Program Change messages can be transmitted and
received. This can be convenient if you want to control more than 128 events on a single
MIDI channel.
When Bank Select and then Program Change messages (in that order) are received on
the Rx channel, the event assigned to that bank number and program number in the
list will be executed.
When you execute a specific event on the CL series console, Bank Select and Program
Change messages for the bank number and program number assigned to that event will
be transmitted on the Tx channel. (If the same event is assigned more than once in the
list, the lowest-numbered bank number and program number will be transmitted.)
NOTE
• The settings of the OMNI and BANK buttons are ignored in Multi mode.
• If the BANK button is on and only a Program Change on an applicable MIDI channel is received,
the last-selected bank number will be used.
• If the BANK button is on, the OMNI button can also be turned on at the same time. In this case,
Bank Select and Program Change messages of all MIDI channels will be received.
3 List
Shows the event (scene recall or library recall) assigned to each MIDI channel and MIDI
Program Change number. The list shows the following items.
• CH/BANK...............If “CH” is shown, this column indicates the MIDI channel (1-16) on
which Program Changes are transmitted/received. If Program
Change transmission and reception is in Single mode and the
BANK button is on, this will be labeled “BANK,” and the numerical
value in this column will correspond to the bank number (1-128).
• NO..........................Indicates the program number 1-128.
• PROGRAM CHANGE EVENT
.........................Indicates the type/number/title of the event assigned to each
channel (bank number) or program number. Press an individual
event display area to access the MIDI PROGRAM CHANGE
window, in which you can select the event that you want to assign.
4 Scroll knob
Press this knob to scroll the list upward or downward using the multifunction knob.
5 CLEAR ALL button
Press this button to erase all events from the list.
6 INITIALIZE ALL button
Press this button to restore all event assignments on the list to their default state.
MIDI PROGRAM CHANGE window
You can specify the event assigned to each program number. Display this window by pressing
the list in the PROGRAM CHANGE page in the MIDI/GPI screen.
1 TYPE field
Enables you to select the type of event.
The following table lists the events you can select.
NO ASSIGN No assignment
SCENE Scene memory recall operations
EFFECT Effect library recall operations
PREMIUM RACK Recall operations for the corresponding Premium Rack library
1 2 3