User Manual

Table Of Contents
Setup
V5 Reference Manual
259
If a device connected to the console is online, and Dante Device Lock is enabled for that
device, the LOCKED indicator will appear in each window as shown below.
If Dante Device Lock is enabled for the console, the following specifications will apply.
The master clock select buttons in the WORD CLOCK/SLOT window cannot be changed.
None of the parameters in the DANTE INPUT PATCH window can be changed. RECALL
and AUTO SETUP in the DANTE INPUT PATCH LIBRARY window will be disabled.
None of the parameters in the I/O DEVICE [OUTPUT PATCH] window can be changed.
If a file is being loaded from USB memory to a device that has Dante Device Lock enabled,
the settings will not be changed by the loaded file. A message is displayed on the screen.
If the consoles internal memory is initialized to the factory settings, Dante Device Lock will
remain enabled and cannot be changed. Locked parameters will also not be initialized.
If the consoles Dante settings are initialized to the factory settings, Dante Device Lock will
be disabled. Locked parameters will also be initialized. R
efer to “Initializing the console settings
and Dante audio network settings” (page 282).
USB memory cannot be used to update the Dante module firmware. In addition, Dante
Firmware Update Manager will not update the firmware.
NOTE
If Dante Device Lock is enabled for a remote device, all offline settings (such as Dante Patch) for
the device will be disabled.
Even if Dante Device Lock is enabled for an I/O device, remote control that is unrelated to Dante
settings (such as HA control for R series) is possible.
Support for Dante Domain Manager
When a DDM server exists in the network, or when enrolling a domain, the DANTE DOMAIN
MANAGER field is shown at the top of the DANTE SETUP screen.
1 STATE
Displays the status of domain participation.
Domain: Domain is enrolled
Disconnected: Domain is enrolled without connecting to the DDM server
Unmanaged: Domain is not enrolled
2 LOCAL
Displays the access status of the Dante settings (including the DANTE PATCH settings)
on the current operating unit.
Read Write: Editing is available
Read Only: Editing is disabled
1 2 3