User Manual
Table Of Contents
- How to Use This Reference Manual
- Contents
- Function Tree
- SELECTED CHANNEL section
- Centralogic section
- Input and output patching
- Input channels
- Signal flow for input channels
- Specifying the channel name/icon
- HA (head amp) settings
- Sending the signal from an input channel to the STEREO/MONO bus
- Added pan function (Monaural input channels only)
- Sending a signal from an input channel to a MIX/ MATRIX bus
- Channel name display indication
- Correcting delay between channels (Input Delay)
- Surround output for input channels
- Channel library operations
- OUTPUT channels
- EQ and Dynamics
- Channel Job
- Scene memory
- Monitor and Cue functions
- Talkback and Oscillator
- Meters
- Graphic EQ, Parametric EQ, Effects, and PREMIUM RACK
- I/O devices and external head amps
- MIDI
- Recorder
- Setup
- About the SETUP screen
- User settings
- Preferences
- USER DEFINED keys
- Functions that can be assigned to USER DEFINED keys
- USER DEFINED knobs
- Functions that can be assigned to USER DEFINED knobs
- Assignable encoders
- Functions that can be assigned to the assignable encoders
- GAIN/PAN/ASSIGN knob (assignable encoder) functions
- Custom fader bank
- Master fader
- Custom fader bank functions
- Console Lock
- Saving and loading setup data to and from a USB flash drive
- Formatting a USB flash drive
- Word clock and slot settings
- Using cascade connections
- Basic settings for MIX buses and MATRIX buses
- Switching the entire phantom power supply on/off
- Specifying the brightness of the touch screen, LEDs, channel name displays, and lamps
- Setting the date and time of the internal clock
- Setting the network address
- Dante audio network settings
- Dante Device Lock
- Support for Dante Domain Manager
- Using GPI (General Purpose Interface)
- Help function
- Other functions
- Initializing the unit to factory default settings
- Adjusting the detection point of the touch screen (Calibration function)
- Adjusting the faders (Calibration function)
- Fine-tuning the input and output gain (Calibration function)
- Adjusting the channel color (Calibration function)
- Adjusting the brightness of the channel name display
- Adjusting the contrast of the channel name display
- Initializing the console settings and Dante audio network settings
- Update procedure for NAME SUB CPU firmware
- Update function to Dante firmware
- Warning/Error Messages
- Index
- Data List
- EQ Library List
- DYNAMICS Library List
- Dynamics Parameters
- Effect Type List
- Effects Parameters
- Premium Rack Processor Parameters
- Parameters That Can Be Assigned to Control Changes
- NRPN Parameter Assignments
- Mixing Parameter Operation Applicability
- MIDI Data Format
- Input/Output Characteristics
- Electrical Characteristics
- Mixer Basic Parameters
- Pin Assignment
- MIDI Implementation Chart
Data List
20
M.BAND COMP
Two input, two output 3-band compressor, with individual solo and gain reduction metering for
each band.
Premium Rack Processor Parameters
Portico5033
This models an analog 5-band EQ made by the RND company.
Portico5043
This models an analog compressor/limiter made by the RND company.
LIM.ATK 0-120 ms Attack time of the limiter
LIM.REL
*1
Release time of the limiter
LIM.KNEE 0-5 Knee of the limiter
LIM.BYP OFF/ON Bypasses the limiter
PRESENCE -10 to +10
Positive (+) values lower the threshold of the high band and raise the
threshold of the low band. Negative (-) values do the opposite. If this is
set to 0, the high, mid, and low bands will be affected in the same way.
LOOKUP 0.0-100.0 ms Lookup delay
MAKE UP OFF/ON Automatically adjusts the output level
*1. 6.0 ms-46.0 s (fs=44.1 kHz), 5.0 ms-42.3 s (fs=48 kHz)
Parameter Range Description
L-M XOVER 21.2 Hz-8.00 kHz Crossover frequency between the low and mid bands
M-H XOVER 21.2 Hz-8.00 kHz Crossover frequency between the mid and high bands
SLOPE -6 dB, -12 dB Filter slope
LOW GAIN -12.0 dB to +12.0 dB Low band gain
MID GAIN -12.0 dB to +12.0 dB Mid band gain
HI. GAIN -12.0 dB to +12.0 dB High band gain
TOTAL -72.0 dB to +12.0 dB Overall gain
CEILING -6.0 dB to 0.0 dB, OFF Restricts the output so that it will not exceed the specified level
LOW THRE -54.0 dB to 0.0 dB Threshold of the low band compressor
LOW RAT 1:1 to 20:1 Ratio of the low band compressor
LOW ATK 0-120 ms Attack time of the low band compressor
LOW REL
*1
*1. 6.0 ms-46.0 s (fs=44.1 kHz), 5.0 ms-42.3 s (fs=48 kHz)
Release time of the low band compressor
LOW KNEE 0-5 Knee of the low band compressor
LOW BYP OFF/ON Bypasses the low band compressor
MID THRE -54.0 dB to 0.0 dB Threshold of the mid band compressor
MID RAT 1:1 to 20:1 Ratio of the mid band compressor
MID ATK 0-120 ms Attack time of the mid band compressor
MID REL
*1
Release time of the mid band compressor
MID KNEE 0-5 Knee of the mid band compressor
MID BYP OFF/ON Bypasses the mid band compressor
HI. THRE -54.0 dB to 0.0 dB Threshold of the high band compressor
HI. RAT 1:1 to 20:1 Ratio of the high band compressor
HI. ATK 0-120 ms Attack time of the high band compressor
HI. RAT
*1
Release time of the high band compressor
HI. KNEE 0-5 Knee of the high band compressor
HI. BYP OFF/ON Bypasses the high band compressor
LOOKUP 0.0-100.0 ms Lookup delay
MAKE UP OFF/ON Automatically adjusts the output level
Parameter Range Description
Parameter Range Description
ALL BYPASS OFF, ON
Turns bypass on/off for the EQ. Even in the bypassed state, the signal will
pass through the input/output transformers and the amp circuit.
TRIM -12.0 to 12.0 dB Input gain
LF FREQ 30.00 to 300.0 Hz Center frequency of the LF band
LF GAIN -12.0 to 12.0 dB Gain of the LF band
LMF IN OFF, ON Switches the LMF band on/off
LMF Q 0.70 to 5.00 Q of the LMF band
LMF FREQ 50.00 to 400.0 Hz Center frequency of the LMF band
LMF GAIN -12.0 to 12.0 dB Gain of the LMF band
MF IN OFF, ON Switches the MF band on/off
MF Q 0.70 to 5.00 Q of the MF band
MF FREQ 330.0 to 2500 Hz Center frequency of the MF band
MF GAIN -12.0 to 12.0 dB Gain of the MF band
HMF IN OFF, ON Switches the HMF band on/off
HMF Q 0.70 to 5.00 Q of the HMF band
HMF FREQ 1.80k to 16.0k Hz Center frequency of the HMF band
HMF GAIN -12.0 to 12.0 dB Gain of the HMF band
LF/HF IN OFF, ON Switches the LF/HF bands on/off
HF FREQ 2.50k to 25.0k Hz Center frequency of the HF band
HF GAIN -12.0 to 12.0 dB Gain of the HF band
Parameter Range Description
IN OFF, ON
Turns bypass on/off for the compressor. When bypassed, the button will
be unlit. However even in the bypassed state, the signal will pass through
the input/output transformers and the amp circuit.
FB OFF, ON Switches between feed-forward type and feed-back type
THRESHOLD -50.0 to 0.0 dB Threshold level
RATIO 1.10 : 1 to 28.9 : 1, LIMIT Compression ratio
ATTACK 20 to 75 ms Attack time
RELEASE 100 ms to 2.50 sec Release time
GAIN -6.0 to 20.0 dB Output level