Described below are the procedures to recover the Dante module integrated in the R series device.
1. Turn off the power to the R series device.
2. Separate the R series device from the Dante network.
3. Connect the Dante [PRIMARY] connector on the rear panel of the R series device to the Ethernet
connector on the computer using an Ethernet cable.
In some cases, an error may occur during recovery if you are going through a network switch. Connect the
computer with the R series device in a one-to-one connection.
4. Turn on the power to the R series device.
5. Disable all but one of the network interfaces on your computer.
You should also disable the wireless LAN.
6. Select [Start]→[All programs]→[Audinate]→[Dante Firmware Update Manager]→[Dante Firmware
Update Manager ] , then right-click and select “Run as Administrator.”
The Dante Firmware Update Manager will start up.
・The "User Account Control" dialog box may appear. Click [Continue] or [Yes].
7. If you see the interface selection screen, select the interface card to connect the Dante device.
8. Click [Failsafe Recovery].