User Manual

Table Of Contents
Yamaha Professional Audio CL StageMix V7 User Guide
Page 88
10.14 Channel Select StageMix Follows Console
When this preference is ON, the currently selected channel in the StageMix
Parametric EQ, Graphic EQ and Dynamics screens will follow the Selected
Channel in the CL series console.
Note: Whenever the selected channel has no GEQ inserted, StageMix closes
the GEQ view and return to the fader view.
Please note, when a GEQ is accessed via the Rack screen in StageMix, then
StageMix will not follow the console selected channel, because the GEQ in
StageMix has been accessed from the rack, not from a channel.
10.15 Channel Select Console Follows StageMix
When this preference is ON, the Selected Channel in the CL series console
will follow the currently selected channel in the Parametric EQ, Graphic EQ
and Dynamics screens of StageMix.
10.16 Input Meter Point
Metering for Input Channels in StageMix can be taken from one of four points
in the signal path:
Pre Digital Gain
Post Digital Gain
Pre Fader
Post On
10.17 Output Meter Point
Metering for Output Channels in StageMix can be taken from one of three
points in the signal path:
Pre EQ
Pre Fader
Post On
10.18 Display Key Input for Dynamics Meters
When this preference is ON, the input meters displayed in the Dynamics
Processor thumbnails in the Mixer window will show the level of the Key Input
signal for every Dynamics Processor. If this preference is Off, the input signal
going into the Dynamics Processors will be displayed.
10.19 RTA Peak Hold Mode
An RTA Hold function is available in the PEQ and GEQ editing screens. The
mode for this function is selected in the Setup screen.
Freeze
When this mode is selected, the RTA display will “freeze” at the moment the
[RTA Hold] button is pressed.
All Peaks
When this mode is selected, the highest level for each RTA frequency band
will be displayed in red, behind the current RTA levels which are displayed in
grey.