Updating the Dante firmware
Described below are the procedures to update the Dante module firmware integrated
in the RMio64-D unit.
To update the Dante firmware, you need to connect an RMio64-D to the computer
one at a time, and repeat the update procedure for each device.
For details of the Dante Firmware Update Manager, refer to “AUD-MAN-
Firmware Update Manager” stored in the compressed file folder.
1.
Connect the Dante [PRIMARY] connector on the rear panel of the RMio64-D unit
to the Ethernet connector on the computer using an Ethernet cable.
Be sure to directly connect the computer and the RMio64-D unit, and do not
connect any other Dante device to the computer.
2.
Turn on the power to the RMio64-D.
3.
Run the Dante Firmware Update Manager as described below.
Windows
Select [All programs] or [All apps] [Audinate] [Dante Firmware Update
Manager] [Dante Firmware Update Manager], then right-click and select “Run
as Administrator.”
Mac
Double-click “Applications” “Dante Firmware Update Manager.”
Confirm in the title bar that the version number is 1.4.7.1 or higher (Windows)
or 1.4.5 or higher (Mac).
The “User Account Control” dialog box may appear. Click [Continue] or [Yes].
4.
If you see the interface selection screen, select the interface card to connect the
Dante device.