User Manual

Description of the Device
NUAGE I/O (16D) / NUAGE I/O (16A) / NUAGE I/O (8A8D) Operation Manual 13
1 [INPUT level meter]
Indicates the input signal level of [ANALOG INPUT]
(page 16) or [AES/EBU] (page 16) on the rear panel.
2 [SAMPLE RATE indicator]
Indicates the sample rate of the device. To select the
sample rate of the device, use the NUAGE Workgroup
Manager (page 19).
3 [CLOCK indicator]
Indicates the word clock source of the device. To select
the word clock source of the device, use the NUAGE
Workgroup Manager (page 19).
The [SYSTEM indicator] indicates the system status of the
device on the Dante network.
The [SYNC indicator] indicates the synchronization status
of the device on the Dante network.
4 [SRC indicator]
Indicates the status of the SRC (sample rate converter),
on (lit) or off (unlit).
When you turn SRC on, even if the sample rate at which
the device is operating differs from the sample rate of the
audio signal input to the device, the SRC function
automatically converts the rate of the signal so that
playback will be correct. SRC is available on every two
adjacent channels. To turn SRC on/off, use the NUAGE
Workgroup Manager (page 19).
5 [OUTPUT level meter]
Indicates the output signal level of [ANALOG OUTPUT]
(page 16) or [AES/EBU] (page 16) on the rear panel.
6 [Power switch]
Turns the power on (I) and off (P). The lamp lights when
the power is on, and is unlit when the power is off.
NOTICE
Rapidly turning the unit on and off in succession can cause it to
malfunction. After turning the unit off, wait for at least 6 seconds
before turning it on again.
Lamp Lighting level
Top (red) 0 dBFS
Second (orange) -3 dBFS or more
Third (orange) -14 dBFS or more
Bottom (green) -48 dBFS or more
Lamp Status Description
Left (green) Lit The device is working properly.
Left (green) Flashes (every
second)
The firmware updating is in
progress.
Right (red) Lit The memory on the device does not
work properly.
Right (red) Flashes (every
second)
The CPU on the device does not
work properly.
Lamp Status Description
Left (green) Lit The device is working as the slave
on the Dante network.
Left (green) Flashes (every
second)
The device is working as the master
on the Dante network.
Right
(orange)
Lit Synchronization with the Dante
network is in progress.
Right
(orange)
Flashes (every
second)
The device is not synchronized with
the Dante network.
Lamp Lighting level
Top (red) 0 dBFS
Second (orange) -3 dBFS or more
Third (orange) -14 dBFS or more
Bottom (green) -48 dBFS or more