User Manual

Voice Parameters
21
Dual LPF Two -12 dB/oct Low-Pass Filters connected in parallel.
You can edit the distance between the two Cutoff Frequencies.
Figure 20: Dual Low-Pass Filters
A: Distance
B: Lower Cutoff Frequency is set directly on the Display
X: Frequency
Y: Level
Dual HPF Two -12 dB/oct High-Pass Filters connected in parallel.
Dual BPF Two -6 dB/oct Band-Pass Filters connected in parallel.
Dual BEF Two -6 dB/oct Band-Eliminate Filters connected in serial.
Figure 21: Dual Band-Eliminate Filters
A: Distance
B: Lower Cutoff Frequency is set directly on the Display
X: Frequency
Y: Level
LPF12+HPF12 A combination of a -12 dB/oct Low-Pass Filter and a -12 dB/oct High-Pass
Filter connected in serial.
When this Filter Type is selected, HPF Cutoff and HPF Key Follow
Sensitivity can be set.
LPF6+HPF6 A combination of a -6 dB/oct Low-Pass Filter and a -6 dB/oct High-Pass
Filter connected in serial.
When this Filter Type is selected, HPF Cutoff and HPF Key Follow
Sensitivity can be set.
Y
B
X
A
Y
B
X
A