Operation Manual

CVP-509/505/503/501 Data List
48
Parameters marked with a
in the “Control” column can be controlled from an AC1
(assignable controller 1) etc. However, these only affect insertion type effects.
Parameter 10 Dry/Wet only affects insertion type effects.
Effect Name
BASIC HALL, LIGHT HALL, HALL 1, 2, 3, 4, 5, HALL M, HALL L, ATMO HALL
ROOM 1, 2, 3, 4, 5, 6, 7, ROOM S, ROOM M, ROOM L, ACOSTIC ROOM, DRUMS ROOM,
PERC ROOM
STAGE 1, 2, 3, 4
PLATE 1, 2, 3, GM PLATE
BALLAD HALL, PIANO HALL, LARGE HALL, MEDIUM HALL
WARM ROOM, WOODY ROOM
RICH PLATE
DELAY LCR1, DELAY LCR2
DELAY LR
ECHO
CROSS DELAY 1, CROSS DELAY 2
ER1, ER2
No. Parameter Display Value See Table Control
1 Reverb Time 0.3 – 30.0s 0 – 69 table#4
2 Diffusion 0 – 10 0 – 10
3 Initial Delay 0.1mS – 200.0mS (*1) 0 – 127 table#5
0.1mS – 99.3mS (*2, *3) 0 – 63
4 HPF Cutoff Thru – 8.0kHz 0 – 52 table#3
5 LPF Cutoff 1.0kHz – Thru 34 – 60 table#3
6
7
8
9
10 Dry/Wet D63>W – D=W – D<W63 1 – 127 table#15
11 Rev Delay 0.1mS – 200.0mS (*1) 0 – 127 table#5
0.1mS – 99.3mS (*2, *3) 0 – 63
12 Density 0 – 4 (*1, *2)
0 – 2 (*3)
0 – 4
13 Er/Rev Balance E63>R – E=R – E<R63 1 – 127
14 High Damp 0.1 – 1.0 1 – 10
15 Feedback Level -63 – +63 1 – 127 table#16
16
No. Parameter Display Value See Table Control
1 Reverb Time 0.3 – 30.0s 0 – 69 table#4
2 Diffusion 0 – 10 0 – 10
3 Initial Delay 0.1mS – 200.0mS 0 – 127 table#5
4 HPF Cutoff Thru – 8.0kHz 0 – 52 table#3
5 LPF Cutoff 1.0kHz – Thru 34 – 60 table#3
6
7
8
9
10 Dry/Wet D63>W – D=W – D<W63 1 – 127 table#15
11
12
13
14 High Damp 0.1 – 1.0 1 – 10
15
16
No. Parameter Display Value See Table Control
1 Lch Delay 0.1 – 1638.3ms (*2)
0.1 – 1486.0ms (*3)
1 – 16383
2 Rch Delay 0.1 – 1638.3ms (*2)
0.1 – 1486.0ms (*3)
1 – 16383
3 Cch Delay 0.1 – 1638.3ms (*2)
0.1 – 1486.0ms (*3)
1 – 16383
4 Feedback Delay 0.1 – 1638.3ms (*2)
0.1 – 1486.0ms (*3)
1 – 16383
5 Feedback Level -63 – +63 1 – 127 table#16
6 Cch Level 0 – 127 0 – 127 table#18
7 High Damp 0.1 – 1.0 1 – 10
8
9
10 Dry/Wet D63>W – D=W – D<W63 1 – 127 table#15
11
12
13 EQ Low Frequency 32Hz – 2.0kHz 4 – 40 table#3
14 EQ Low Gain -12 – +12dB 52 – 76
15 EQ High Frequency 500Hz – 16.0kHz 28 – 58 table#3
16 EQ High Gain -12 – +12dB 52 – 76
No. Parameter Display Value See Table Control
1 Lch Delay 0.1 – 1638.3ms (*2)
0.1 – 1486.0ms (*3)
1 – 16383
2 Rch Delay 0.1 – 1638.3ms (*2)
0.1 – 1486.0ms (*3)
1 – 16383
3 Feedback Delay 1 0.1 – 1638.3ms (*2)
0.1 – 1486.0ms (*3)
1 – 16383
4 Feedback Delay 2 0.1 – 1638.3ms (*2)
0.1 – 1486.0ms (*3)
1 – 16383
5 Feedback Level -63 – +63 1 – 127 table#16
6 High Damp 0.1 – 1.0 1 – 10
7
8
9
10 Dry/Wet D63>W – D=W – D<W63 1 – 127 table#15
11
12
13 EQ Low Frequency 32Hz – 2.0kHz 4 – 40 table#3
14 EQ Low Gain -12 – +12dB 52 – 76
15 EQ High Frequency 500Hz – 16.0kHz 28 – 58 table#3
16 EQ High Gain -12 – +12dB 52 – 76
No. Parameter Display Value See Table Control
1 Lch Delay1 0.1 – 1486.0ms (*2)
0.1 – 743.0ms (*3)
1 – 14860
2 Lch Feedback Level -63 – +63 1 – 127 table#16
3 Rch Delay1 0.1 – 1486.0ms (*2)
0.1 – 743.0ms (*3)
1 – 14860
4 Rch Feedback Level -63 – +63 1 – 127 table#16
5 High Damp 0.1 – 1.0 1 – 10
6 Lch Delay2 0.1 – 1486.0ms (*2)
0.1 – 743.0ms (*3)
1 – 14860
7 Rch Delay2 0.1 – 1486.0ms (*2)
0.1 – 743.0ms (*3)
1 – 14860
8 Delay2 Level 0 – 127 0 – 127 table#18
9
10 Dry/Wet D63>W – D=W – D<W63 1 – 127 table#15
11
12
13 EQ Low Frequency 32Hz – 2.0kHz 4 – 40 table#3
14 EQ Low Gain -12 – +12dB 52 – 76
15 EQ High Frequency 500Hz – 16.0kHz 28 – 58 table#3
16 EQ High Gain -12 – +12dB 52 – 76
No. Parameter Display Value See Table Control
1 L->R Delay 0.1 – 1486.0ms (*2)
0.1 – 743.0ms (*3)
1 – 14860
2 R->L Delay 0.1 – 1486.0ms (*2)
0.1 – 743.0ms (*3)
1 – 14860
3 Feedback Level -63 – +63 1 – 127 table#16
4 Input Select L, R, L&R 0 – 2
5 High Damp 0.1 – 1.0 1 – 10
6
7
8
9
10 Dry/Wet D63>W – D=W – D<W63 1 – 127 table#15
11
12
13 EQ Low Frequency 32Hz – 2.0kHz 4 – 40 table#3
14 EQ Low Gain -12 – +12dB 52 – 76
15 EQ High Frequency 500Hz – 16.0kHz 28 – 58 table#3
16 EQ High Gain -12 – +12dB 52 – 76
No. Parameter Display Value See Table Control
1Type S-H, L-H, Rdm, Rvs, Plt, Spr 0 – 5
2 Room Size 0.1 – 20.0 0 – 127 table#6
3 Diffusion 0 – 10 0 – 10
4 Initial Delay 0.1mS – 200.0mS 0 – 127 table#5
5 Feedback Level -63 – +63 1 – 127 table#16
6 HPF Cutoff Thru – 8.0kHz 0 – 52 table#3
7 LPF Cutoff 1.0kHz – Thru 34 – 60 table#3
8
9
10 Dry/Wet D63>W – D=W – D<W63 1 – 127 table#15
11 Liveness 0 – 10 0 – 10
12 Density 0 – 3 0 – 3
13 High Damp 0.1 – 1.0 1 – 10
14
15
16
No. Parameter Display Value See Table Control
Effect Parameter List / Liste der Effektparameter /
Liste des paramètres d’effets / Lista de parámetros de efectos