Operation Manual

CVP-109/107/105/103/700
26
MIDI Data Format
/
MIDI-Datenformat
/
Format des données MIDI
/
Formato de datos MIDI
03 0n 30 2 00..7F Ins. Param.1 MSB Refer to the Ef. Parameter List
00..7F Ins. Param.1 LSB Refer to the Ef. Parameter List
03 0n 32 2 00..7F Ins. Param.2 MSB Refer to the Ef. Parameter List
00..7F Ins. Param.2 LSB Refer to the Ef. Parameter List
03 0n 34 2 00..7F Ins. Param.3 MSB Refer to the Ef. Parameter List
00..7F Ins. Param.3 LSB Refer to the Ef. Parameter List
03 0n 36 2 00..7F Ins. Param.4 MSB Refer to the Ef. Parameter List
00..7F Ins. Param.4 LSB Refer to the Ef. Parameter List
03 0n 38 2 00..7F Ins. Param.5 MSB Refer to the Ef. Parameter List
00..7F Ins. Param.5 LSB Refer to the Ef. Parameter List
03 0n 3A 2 00..7F Ins. Param.6 MSB Refer to the Ef. Parameter List
00..7F Ins. Param.6 LSB Refer to the Ef. Parameter List
03 0n 3C 2 00..7F Ins. Param.7 MSB Refer to the Ef. Parameter List
00..7F Ins. Param.7 LSB Refer to the Ef. Parameter List
03 0n 3E 2 00..7F Ins. Param.8 MSB Refer to the Ef. Parameter List
00..7F Ins. Param.8 LSB Refer to the Ef. Parameter List
03 0n 40 2 00..7F Ins. Param.9 MSB Refer to the Ef. Parameter List
00..7F Ins. Param.9 LSB Refer to the Ef. Parameter List
03 0n 42 2 00..7F Ins. Param.10 MSB Refer to the Ef. Parameter List
00..7F Ins. Param.10 LSB Refer to the Ef. Parameter List
TOTAL SIZE 14
For effect types that do not require MSB, the Parameters for Address 02-0B will be received. Address 30-42 will not be received.
For effect types that require MSB, the Parameters for Address 30-42 will be received. Address 02-0B will not be received.
When Bulk Dumps that include Effect Type data are transmitted, the Parameters for Address 02 - 0B will always be transmitted. But, effects that require MSB, when the bulk dump is received the
Parameters for Address 02 - 0B will not be received.
n = Insertion Effect No. (0 - 2)
The INSERTION EFFECT Parameter cannot be reset to its factory settings with XG SYSTEM ON or XG ALL PARAMETER RESET, there is no default value.
When a Parameter Request or Bulk Request message is received, the currently set value is always transmitted.
< Table 1-7 >
MIDI PARAMETER CHANGE TABLE (SPECIAL EFFECT) (CVP-109/107/700)
Address Size Data Parameter Description Default
(H) (H) (H)
04 00 00 2 00 - 7F Insertion Effect Type MSB Refer to the XG Effect Map
00 - 7F Insertion Effect Type LSB 00 : basic type
02 1 00 - 7F Insertion Effect Parameter1 Refer to the XG Ef. Parameter List
03 1 00 - 7F Insertion Effect Parameter2 Refer to the XG Ef. Parameter List
04 1 00 - 7F Insertion Effect Parameter3 Refer to the XG Ef. Parameter List
05 1 00 - 7F Insertion Effect Parameter4 Refer to the XG Ef. Parameter List
06 1 00 - 7F Insertion Effect Parameter5 Refer to the XG Ef. Parameter List
07 1 00 - 7F Insertion Effect Parameter6 Refer to the XG Ef. Parameter List
08 1 00 - 7F Insertion Effect Parameter7 Refer to the XG Ef. Parameter List
09 1 00 - 7F Insertion Effect Parameter8 Refer to the XG Ef. Parameter List
0A 1 00 - 7F Insertion Effect Parameter9 Refer to the XG Ef. Parameter List
0B 1 00 - 7F Insertion Effect Parameter10 Refer to the XG Ef. Parameter List
0C 1 00 - 7F Insertion Effect Part Part1...16(0...15)
AD1(64)
OFF(16...63, 65...127)
0D 1 00 - 7F MW Insertion Control Depth Don’t care
0E 1 00 - 7F BEND Insertion Control Depth Don’t care
0F 1 00 - 7F CAT Insertion Control Depth Don’t care
10 1 00 - 7F AC1 Insertion Control Depth Don’t care
11 1 00 - 7F AC2 Insertion Control Depth Don’t care
TOTAL SIZE 12
04 00 14 1 00 - 7F
Unique Insertion Effect External
1...16(0...15), off(127)
Control CH1(Harmony Channel)
15 1 00 - 7F
Unique Insertion Effect External
1...16(0...15), off(127)
Control CH2 (MELODY CHANNEL)
TOTAL SIZE 2
04 00 20 1 00 - 7F Insertion Effect Parameter11 Refer to the XG Ef. Parameter List
21 1 00 - 7F Insertion Effect Parameter12 Refer to the XG Ef. Parameter List
22 1 00 - 7F Insertion Effect Parameter13 Refer to the XG Ef. Parameter List
23 1 00 - 7F Insertion Effect Parameter14 Refer to the XG Ef. Parameter List
24 1 00 - 7F Insertion Effect Parameter15 Refer to the XG Ef. Parameter List
25 1 00 - 7F Insertion Effect Parameter16 Refer to the XG Ef. Parameter List
TOTAL SIZE 6
Insertion Effect Type MSB: Assigns the Harmony Mode.
If the value is not a Harmony Mode value, the Harmony function will be OFF and the input signal will be transmitted as is.
Insertion Effect Type LSB: Assigns the Harmony Kit.
If the value is not an existing harmony kit value, don’t care.
Harmony Channel: Harmony control channel.
Melody Channel: Melody play channel.
When both are received, the last message received will take priority.
For example, when the Melody Channel is 3 and the Harmony Channel 3 message is received, the Melody Channel will be OFF and the Harmony Channel will be 3.
Note) The SPECIAL EFFECT Parameter cannot be reset to its factory settings with XG SYSTEM ON or XG ALL PARAMETER RESET, there is no default value.
When a request message is received, the currently set value is always transmitted.