PROFESSIONAL DIGITAL DELAY OPERATING MANUAL MANUEL D’UTILISATION BEDIENUNGSHANDBUCH DATA ENTRY INPUT LEVEL L -00 L YDG2030 R +10 CURSOR PARAMETER POWER MIX 0 DRY WET CLIP -6 -12 -18 -24 -30 -36 -42 R PROFESSIONAL DIGITAL DELAY PROGRAM STORE RECALL DELAY FB MOD DUCK PROGRAM TRIGGER UTILITY BYPASS ON OFF
FCC INFORMATION (U.S.A.) CANADA 1. IMPORTANT NOTICE: DO NOT MODIFY THIS UNIT! This product, when installed as indicated in the instructions contained in this manual, meets FCC requirements. Modifications not expressly approved by Yamaha may void your authority, granted by the FCC, to use the product. This digital apparatus does not exceed the “Class B” limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulation of the Canadian Department of Communications. 2.
Contents Introduction.............................................................................................................. 2 Precautions ............................................................................................................... 3 The front panel ......................................................................................................... 4 The back panel ..........................................................................................................
2 - Introduction Introduction With its high-quality 20-bit sound, the Yamaha D5000 Professional Digital Delay is the perfect choice for studio and sound reinforcement applications. It has four types of effect programs: DUAL (stereo) delay, SINGLE (mono) delay, FREEZE record and playback, and S&H (sample and hold) playback. The large amount of memory allows it to create delay lines or record samples of up to 10 seconds in duration.
Precautions - 3 Precautions Avoid excessive heat, humidity, dust, and vibration Keep the unit away from locations where it is likely to be exposed to high temperatures or humidity - such as near radiators, stoves, in direct sunlight, etc. Avoid locations which are subject to excessive dirt accumulation. Extreme vibrations can cause mechanical damage. Avoid physical shocks Strong physical shocks can damage the unit. Handle it with care.
4 - The front panel The front panel 8 DATA ENTRY INPUT LEVEL L R +10 1 PARAMETER POWER MIX 0 -00 L CURSOR DRY CLIP -6 -12 -18 -24 -30 -36 -42 R PROFESSIONAL DIGITAL DELAY STORE PROGRAM RECALL DELAY FB MOD DUCK PROGRAM TRIGGER UTILITY BYPASS WET 2 ON 3 4 5 6 7 9 0 A B OFF C 1 INPUT LEVEL – The two concentric rotary controls are used to adjust the level of the input signal. The inner control adjusts the left channel and the outer control adjusts the right channel.
The back panel - 5 The back panel 7 6 FOOT SW BYPASS TRIGGER PROGRAM INC/DEC MIDI OUTPUT R L INPUT R L IN R THRU OUT 12 3 4 5 L R L 20dB +4dB -20dB +4dB 8 8 1 BYPASS or PROGRAM INC/DEC Footswitch Jack – The function of this jack is determined by the FOOT SW FUNCTION parameter of the UTILITY Mode. If it is set to BYPASS, the footswitch duplicates the function of the [BYPASS] key.
6 - System structure System structure The D5000 has three operational modes: • Program Select Mode - Use this mode to STORE and RECALL programs. • Parameter Edit Mode - This mode allows you to edit the various operational parameters, the DELAY/FREEZE parameters, the FB (feedback) parameters, the MOD (modulation) parameters, and the DUCK parameters. The Parameter Edit Mode performs differently according to which program type is active. DUAL (stereo) and SINGLE (mono) programs are delay programs.
Program Select Mode - 7 Program Select Mode About the programs of the D5000 The D5000 has 100 user programs. All of the programs are user-programmable. There are four types of programs available: • DUAL (stereo) Delay (refer to the diagram on page 100) There are two delay units (A-channel and B-channel) and three taps for each unit. Create a flanger or chorus in perfect stereo, or a ping-pong (channel-to-channel) delay. • SINGLE (mono) Delay This is a single delay with six taps.
8 - Program Select Mode Press the [ > ] "RECALL" CURSOR key. If you have not made any changes to the previous settings, it will be replaced with the new program. If you have made changes to the previous settings without storing them, the unit will additionally display the message "Are you sure?" on the LCD. Press the [ > ] "RECALL" CURSOR key again to complete your selection. The previous program will be replaced with the new program.
Parameter Edit Mode - 9 Parameter Edit Mode The D5000 has four types of effect program. The first two are high-quality, multi-tap digital delays, either DUAL (stereo) or SINGLE (mono). The other two are sampling/playback recorder programs. Editing a delay program To edit a delay program, press one of the PARAMETER keys, [ DELAY ] , [ FB ] , [ MOD ] , or [ DUCK ] . The first step is usually to select the main delay parameters by pressing the [ DELAY ] key. The D5000 features multi-tap delays.
10 - Parameter Edit Mode TEMPO = (25 ~ 250 beats per minute). Select one of the 3 3 following for the Note parameter: , , , 3 3 , , , , , , , , , , , or . 30FRAME SINGLE (~ 10 s 12 f 00 b) or DUAL (~ 5 s 6 f 00 b). 25FRAME SINGLE (~ 10 s 10 f 00 b) or DUAL (~ 5 s 5 f 00 b). 24FRAME SINGLE (~ 10 s 9 f 48 b) or DUAL (~ 5 s 4 f 64 b). LVL (0 ~ 100%) Set the level of the delay tap. PAN (L16 ~ L=R ~ R16) Set the stereo pan position of the delay tap in one of 33 steps.
Parameter Edit Mode - 11 Page 2 parameters INPUT MODE (STEREO/ L-MONO) Set the input mix mode. The following diagram illustrates the different INPUT MODE options. STEREO Lch Delay Rch Delay DUAL Delay L-MONO Lch Lch Delay Rch Rch Delay Lch Lch PAN Lch SINGLE Delay Delay PAN Rch Rch Lch Delay PAN Rch Lch PAN Rch Rch * * The levels of the Lch and Rch input signals are halved and mixed. DISPLAY UNIT (units) Select the unit that will be used to display the delay time.
12 - Parameter Edit Mode Press the [ DELAY ] key again to select the last display page. Use the [ < ] , [ ^ ] , [ > ] , and [ % ] CURSOR keys to move through the various parameters. Modify the parameter by rotating the DATA ENTRY encoder. Page 3: parameters Use the [ < ] and [ > ] CURSOR keys to move along the line of text. Change the letter under the cursor by rotating the DATA ENTRY encoder.
Parameter Edit Mode - 13 HPF (20 Hz ~ 4.0 kHz or THRU) Set the cutoff frequency for the high pass filter for the feedback loop. LPF (400 kHz ~ 20 kHz or THRU) Set the cutoff frequency for the low pass filter for the feedback loop. NOTE You should ensure the total value of the LVL parameter of each channel for a DUAL delay or all taps for a SINGLE delay is kept at or below 100. For example, if you have three taps active, set the values for each tap to 30.
14 - Parameter Edit Mode Ducking/gating the delay When you set ducking, the delay effect is only applied to the signal when the input level drops below the threshold you set. If you select the gate, the delay effect is applied to the signal when the control level exceeds the threshold. You can also use the [TRIGGER] key or a footswitch, or a MIDI Note Off/On message to trigger the duck/gate. Press the [ DUCK ] key to select DUCK. Use the [ ^ ] and [ % ] CURSOR keys to move through the various parameters.
Parameter Edit Mode - 15 of a DUCK) for a very short time. This can sound unnatural, especially if the GATE closes abruptly. There are two parameters which you can adjust, HOLD and RELEASE. By setting a long HOLD time, the gate can be kept open even after the signal has dropped below the threshold. The RELEASE parameter specifies the length of time it takes for the gate to close, causing the signal to gradually cut off.
16 - Parameter Edit Mode Editing a sampling/playback program To edit a sampling/playback program, press the [ DELAY ] key. FREEZE program The FREEZE program allows you to sample (digitally record) and playback sounds. You can record in stereo for a maximum of 5.2 seconds or in mono for a maximum of 10.4 seconds. For playback, you can adjust the pitch of the sample by up to ± two octaves. NOTE You cannot store the recorded sample.
Parameter Edit Mode - 17 AUTO MODE (RECORD/OVERDUB/ CAPTURE) TRG.DLY (-1000 ~ +1000 ms) TRG.DLY = 0 Press the [ TRIGGER ] key or step on a footswitch connected to the TRIGGER Footswitch Jack to put the D5000 in standby mode. Recording will start automatically when the input signal is higher than the specified threshold. Select a recording mode. RECORD Create a new recording. OVERDUB Combine the new recording with existing data.
18 - Parameter Edit Mode Page 2: Setting the playback parameters Press the [ DELAY ] key again to switch to the second page of the FREEZE program. Use the [ ^ ] and [ % ] CURSOR keys to move through the various parameters. Modify the selected parameter by rotating the DATA ENTRY encoder. FREEZE PLAY parameters MODE (MOMENTARY/ CONTINU./INPUT TRG) Select the playback mode.
Parameter Edit Mode - 19 Sample Sample START END Playback START END Playback * Sound is reversed START END START END Playback * Sound is reversed Playback Playback loop You can set a loop point within the sample. This sets the start point for repeats after the first playback. Sample START LOOP Sample END END LOOP START Playback Playback * Sound is reversed Page 3: Setting the pitch and MIDI note number Press the [ DELAY ] key again to select the third page of the FREEZE program.
20 - Parameter Edit Mode FINE (-100 ~ +100) Fine tune the pitch by ±100 cents. BASE KEY (OFF, C 1 ~ C 6) Specify the note that will be centre frequency for MIDI Note On messages. The D5000 calculates the pitch change as the difference between the BASE KEY and the note number of the pressed key. For example, if the BASE KEY is set to "C3", then pressing C3 will produce a Unison playback, while pressing C4 will shift the pitch up one octave, and pressing G2 will produce a pitch change of 5 semitones down.
Parameter Edit Mode - 21 The sample and hold function is controlled by the [ TRIGGER ] key or by a footswitch connected to the TRIGGER Footswitch Jack. [TRIGGER] key or Footswitch STOP [TRIGGER] key or Footswitch RECORD PLAYBACK (Loop) [TRIGGER] key or Footswitch STOP As you press the [ TRIGGER ] key or step on the footswitch, the LCD will display the following sequence of messages: STOP Indicates that the S&H function is ready to begin recording.
22 - Utility Mode Utility Mode The [ UTILITY ] key allows you to access the system parameters. Each time you press the key, the D5000 cycles to the next command: SOFTWARE PROTECT PARAMETER DISPLAY REPEAT DELAY FOOT SW FUNCTION MIDI SETUP PARAMETER COPY MIDI BULK DUMP MIDI CONTROLLER Until you select one of the other modes, the LED set in the [ UTILITY ] key remains lit. NOTE The "REPEAT DELAY" function is not accessible when FREEZE or S&H (sample and hold) programs are active.
Utility Mode - 23 PARAMETER DISPLAY Press the [ UTILITY ] key to select the PARAMETER DISPLAY command. Change the MODE from "NORMAL" to "DETAIL(AUTO)" or "DETAIL(HOLD)" by rotating the DATA ENTRY encoder. When the PARAMETER DISPLAY is set to "DETAIL(AUTO)" or "DETAIL(HOLD)", the parameters are displayed in a large, easy-to-read font in a pop-up sub-window. A bar graph is also displayed, giving you a visual indication of the parameter’s status.
24 - Utility Mode When the FOOT SW FUNCTION is set to PROGRAM, the D5000 switches to the next program each time you press the footswitch. When the last program in the range (TO) is the current program, when you press the footswitch again, it will select the first program again.
Utility Mode - 25 MIDI CONTROLLER Each D5000 program (except for Sample and Hold programs) can accept input from two MIDI controllers. These parameters allow you to assign a MIDI controller number to the controller channels of the programs (see page 12). Press the [ UTILITY ] key to select the MIDI CONTROLLER command. Use the [ ^ ] and [ % ] CURSOR keys to move through the various parameters. Modify the selected parameter by rotating the DATA ENTRY encoder.
26 - Utility Mode BULK DUMP procedure The D5000 should be correctly connected to an external MIDI device, for example, a MIDI data filer such as the Yamaha MDF2. Set the desired parameters. Make certain that the external MIDI device is ready to receive your data. To execute the MIDI bulk dump request, press the [ < ] "STORE" CURSOR key. While the bulk dump is in progress, the message "BULK OUT..." will be displayed at the bottom of the screen.
Utility Mode - 27 REPEAT DELAY This command is only available for the delay programs. It allows you to very rapidly create linear delay programs. If you select a FREEZE or an S&H (sample and hold) program, this display page will not appear. Press the [ UTILITY ] key to select the REPEAT DELAY command. Use the [ ^ ] and [ % ] CURSOR keys to move through the various parameters. Modify the selected parameter by rotating the DATA ENTRY encoder. To execute the repeat delay, press the [ < ] "STORE" CURSOR key.
28 - How to initialize the D5000 How to initialize the D5000 You can reset all programs and system parameters back to their original factory settings with the following procedure: • While pressing the [ < ] "STORE" CURSOR key, turn the power on. • The LCD will display the message "Press [RECALL] to initialize". • Press the [ > ] "RECALL" CURSOR key. The message "Initializing now..." will momentarily appear on the LCD. Then the D5000 will default to Program Select Mode.
Specifications - 29 Specifications Audio quality ("WET" circuit) Inputs Outputs A/D and D/A converters Frequency Response 20 Hz to 20 kHz +/-1.0 dB Dynamic Range greater than 100 dB Hum and Noise less than -76 dB Distortion less than 0.007% (max.
30 - Preset Program Library Preset Program Library Program number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 97 98 99 00 Title T120 Single 15 T120 1/4 & 1/8 Double Slap Short Single Short Double Medium Double Long Single Long Double Long FB Double Long FB Duck Long FB Gate Light Vocal Vocal Template 1 Vocal Template 2 Vocal Template 3 Ambience Dimension Mod.
100 - Block diagram/Schéma de principe/Blockdeagramm Block diagram/Schéma de principe/Blockdeagramm Single D5000 Block Diagram (mono type) 1994.04.
Dimensions/Abmessungen - 101 Dimensions/Abmessungen 305.4 3.6 D:336.4 21 28.5 230.5 50 6.4 440 44 1.2 H:45.
102 - MIDI Data format MIDI Data format 1. Transmission Conditions MIDI CH OFF BULK DATA (F0H,43H,0nH) OMNI, 1~ 16 2. CH = ? MIDI OUT Transmission Data 1) System Exclusive Messages 1 Program Bulk Data When a MIDI BULK DUMP operation is performed with the "PROGRAM" ITEM selected or when a Program Bulk Data Request message is received, the data is transmitted on the currently set MIDI channel. If the program is set to "ALL", data is transmitted from program 1 to program 00 (100).
MIDI Data format - 103 Checksum EOX 0eeeeeee 11110111 (F7H) 3 System Set-up Bulk Data When a MIDI BULK DUMP operation is performed with the "SYSTEM" ITEM selected or when a System Set-up Bulk Data Request message is received, the data is transmitted on the currently set MIDI channel.
104 - MIDI Data format 3. Reception Data and Conditions BASE KEY OFF ON (C1 ~ C6) NOTE ON (9nH) OMNI MIDI CH MIDI IN NOTE OFF (8nH) 1~ 16 CONTROL CHANGE (BnH) CH = ? PROGRAM CHANGE (CnH) BULK DUMP REQUEST (F0H,43H,2nH) OFF BULK DUMP (F0H,43H,0nH) BANK CHANGE (F0H,43H,0nH) SYSTEM REAL TIME (F8H) 4. Reception Data 1) Channel Voice Messages 1 Note Off Received on the currently set MIDI channel (if set to OMNI, all channels received).
MIDI Data format - 105 Data Name Program EOX 00110110 00110011 01001101 0ppppppp 11110111 (36H) (33H) (4DH) ASCII “6” ASCII “3” ASCII “M” p = 1 (program 1) ~ 100 (program 00) (F7H) 2 Program Change Bank Bulk Data Request Received on the currently set MIDI channel. When a message is received, the data for the requested bank is transmitted.
106 - MIDI Data format Header Data Name Version Number Bank Number Checksum EOX 01001100 01001101 00100000 00100000 00111000 01000001 00110110 00110011 01010101 00100000 0vvvvvvv 0rrrrrrr 0zzzzzzz 0eeeeeee 11110111 (4CH) (4DH) (20H) (20H) (38H) (41H) (36H) (33H) (55H) (20H) ASCII "L” ASCII "M” ASCII " ” ASCII " ” ASCII "8” ASCII "A” ASCII "6” ASCII "3” ASCII "U” ASCII " ” v=1 r=0 z = 1 ~ 7 (1=A, 2=B, 3=C, 4=D, 5=E, 6=F, 7=G) (F7H) 6 Program Bulk Data The data format for transmission is the same as for
D5000 Parameter List - 107 D5000 Parameter List PROGRAM No. DATE: TITLE: PROGRAMMER: INPUT MODE: STEREO . L-MONO TYPE: DELAY TEMPO: DUCK NOTE B . DUAL . SINGLE DISPLAY UNIT: SECOND. DISTANCE. TEMPO. 30FRAME. 25FRAME. 24FRAME A . TIME LEVEL PAN [OFF . ON] TYPE 1 OFF. NOR INV SOURCE 2 OFF. NOR INV TARGET 3 OFF. NOR INV HOLD 4 OFF. NOR INV RELEASE 5 OFF. NOR INV THRESHOLD 6 OFF. NOR INV OUTPUT FB OUT LEVEL OFF. ON A B LEVEL 1 OFF. NOR INV A.B 2 OFF. NOR INV A.
YAMAHA [PROFESSIONAL DIGITAL DELAY] Date:07-JUL-1994 Model D5000 MIDI Implementation Chart Version : 1.0 +-----------------------------------------------------------------------+ | | Transmitted | Recognized | Remarks | | Function ...
VS10980 R1 1 CR 94 11 500 CR Printed in Japan P.O.