User Guide
Table Of Contents
- Important Information
- Contents
- 1 Welcome
- 2 Control Surface & Rear Panel
- 3 Operating Basics
- Connecting the Power Cord
- Turning On & Off the DM2000
- About the Display
- Selecting Display Pages
- Display History
- Display Page Controls
- Parameter Windows
- Confirmation Messages
- Title Edit Window
- Using a Keyboard
- Channel Strip Displays
- Selecting Layers
- Selecting Channels
- Selecting Fader Modes
- Selecting Encoder Modes
- Assigning Parameters to the ENCODER MODE Assign Buttons
- 4 Analog I/O & the AD Input Section
- 5 Digital I/O & Cascading
- 6 Input & Output Patching
- 7 Input Channels
- Patching Input Channels
- Metering Input Channels
- Reversing the Signal Phase
- Gating Input Channels
- Attenuating Input Channels
- EQ’ing Input Channels
- Grouping Input Channel EQs
- Input Channel Inserts
- Compressing Input Channels
- Grouping Input Channel Compressors
- Delaying Input Channels
- Muting Input Channels (ON/OFF)
- Grouping Input Channel Mutes (ON/OFF)
- Input Channel Mute Master
- Setting Input Channel Levels
- Grouping Input Channel Faders
- Group Master for Input Channel Faders
- Routing Input Channels
- Panning Input Channels
- Using Surround Pan
- Assigning Surround Channels to Buses
- Sending Input Channels to Aux Sends
- Soloing Input Channels
- Direct Outs
- Pairing Input Channels
- Viewing Input Channel Settings
- Copying Input Channel Settings
- Naming Input Channels
- Using the MS Stereo Microphone
- 8 Stereo Out
- Stereo Out Connectors
- Patching the Stereo Out to Outputs
- Routing Input Channels to the Stereo Out
- Sending Bus Outs to the Stereo Out
- Metering the Stereo Out
- Monitoring the Stereo Out
- Attenuating the Stereo Out
- EQ’ing the Stereo Out
- Grouping Master EQs
- Stereo Out Inserts
- Compressing the Stereo Out
- Grouping Master Compressors
- Muting the Stereo Out (ON/OFF)
- Grouping Master Mutes (ON/OFF)
- Setting the Stereo Out Level
- Grouping Master Faders
- Sending the Stereo Out to the Matrix Sends
- Balancing the Stereo Out
- Delaying the Stereo Out
- Inserting GEQs
- Viewing Stereo Out Settings
- Copying Stereo Out Settings
- Naming the Stereo Out
- 9 Bus Outs
- Patching Bus Outs to Outputs
- Routing Input Channels to Bus Outs
- Metering Bus Outs
- Monitoring Bus Outs
- Attenuating Bus Outs
- EQ’ing Bus Outs
- Grouping Master EQs
- Bus Out Inserts
- Compressing Bus Outs
- Grouping Master Compressors
- Muting Bus Outs (ON/OFF)
- Grouping Master Mutes (ON/OFF)
- Setting Bus Out Levels
- Grouping Master Faders
- Sending Bus Outs to Matrix Sends
- Delaying Bus Outs
- Inserting GEQs
- Soloing Bus Outs
- Pairing Bus Outs
- Sending Bus Outs to the Stereo Out
- Viewing Bus Out Settings
- Copying Bus Out Settings
- Naming Bus Outs
- 10 Aux Sends
- Patching Aux Send Masters to Outputs
- Setting the Aux Send Mode
- PreFader or PostFader Aux Sends
- Setting Aux Send Levels
- Muting Aux Sends (ON/OFF)
- Aux Send Pages
- Viewing Aux Send Settings
- Panning Aux Sends
- Excluding Certain Channels from Aux Sends (Mix Minus)
- Copying Channel Fader Positions to Aux Sends
- Metering Aux Send Masters
- Monitoring Aux Send Masters
- Attenuating Aux Send Masters
- EQ’ing Aux Send Masters
- Grouping Master EQs
- Aux Send Master Inserts
- Compressing Aux Send Masters
- Grouping Master Compressors
- Muting Aux Send Masters (ON/OFF)
- Grouping Master Mutes (ON/OFF)
- Settings Aux Send Master Levels
- Grouping Master Faders
- Sending Aux Sends to Matrix Sends
- Delaying Aux Send Masters
- Inserting GEQs
- Soloing Aux Sends
- Pairing Aux Sends
- Viewing Aux Send Master Settings
- Copying Aux Send Master Settings
- Naming Aux Send Masters
- 11 Matrix Sends
- Patching Matrix Send Masters to Outputs
- PreFader or PostFader Matrix Sends
- Setting Matrix Send Levels
- Muting Matrix Sends (ON/OFF)
- Matrix Send Pages
- Panning Matrix Sends
- Viewing Matrix Send Settings
- Metering Matrix Send Masters
- Monitoring Matrix Send Masters
- Attenuating Matrix Send Masters
- EQ’ing Matrix Send Masters
- Grouping Master EQs
- Matrix Send Master Inserts
- Compressing Matrix Send Masters
- Grouping Master Compressors
- Muting Matrix Send Masters (ON/OFF)
- Grouping Master Mutes (ON/OFF)
- Setting Matrix Send Master Levels
- Grouping Master Faders
- Balancing Matrix Send Masters
- Delaying Matrix Send Masters
- Soloing Matrix Sends
- Inserting GEQs
- Viewing Matrix Send Master Settings
- Copying Matrix Send Master Settings
- Naming Matrix Send Masters
- 12 Common Channel Functions
- Metering
- Attenuating Signals
- Using EQ
- Grouping Output Channel EQs
- Using Inserts
- Compressing Channels
- Grouping Output Channel Compressors
- Delaying Channel Signals
- Soloing Channels
- Pairing Channels
- Grouping Output Channel Faders
- Group Master for the Output Channel Faders
- Grouping Output Channel Mutes (ON/OFF)
- Output Channel Mute Master
- Viewing Channel Parameter Settings
- Viewing Channel Fader Settings
- Copying Channel Settings
- Naming Channels
- 13 Monitoring & Talkback
- 14 Libraries
- 15 Internal Effects, PlugIns & GEQs
- 16 Scene Memories
- 17 Automix
- About Automix
- What’s Recorded in an Automix?
- Automix Main Page
- AUTOMIX Section
- Channel Strip [AUTO] Buttons
- Automix Memory Page
- Fader Edit Pages
- Selecting the Timecode Source & Frame Rate
- Creating a Time Signature Map
- Recording an Automix
- Inserting Mix Parameters into Automix
- Rerecording Events
- Parameter Recording
- Punching In & Out Individual Parameters
- Playing Back an Automix
- Editing Events Offline
- 18 MIDI
- 19 Pro Tools Remote Layer
- Configuring Windows Computers
- Configuring Macintosh Computers (MacOS 8.6 to 9.2.2)
- Configuring Macintosh Computer (MacOS X)
- Configuring the DM2000
- Configuring Pro Tools
- Control Surface Operation with the Pro Tools Remote Layer
- Scrolling Windows
- Selecting Channels
- Assigning Inputs to Channels
- Assigning Outputs to Channels
- Setting Channel Levels
- Muting Channels
- Panning Channels
- Soloing Channels
- Assigning Send Destinations
- Configuring Sends as Pre or Post
- Setting Send Levels
- Muting Sends
- Panning Sends
- Flip Mode
- Assigning Inserts/Plugins
- Editing Plugins
- Bypassing Individual Plugins
- Bypassing all Plugins
- Resetting Faders, Sends, Panpots & Plugins
- Navigating the Edit Window
- Zooming
- Making Fine Adjustments to the Selected Region
- Scrub & Shuttle
- Automation
- Panner
- 20 Remote Control
- 21 Other Functions
- Appendix A: Parameter Lists
- USER DEFINED KEYS
- USER DEFINED KEYS Initial Assignments
- Input Patch Parameters
- Initial Input Patch Settings
- Output Patch Parameters
- Initial Output Patch Settings
- Initial Input Channel Names
- Initial Output Channel Names
- Initial Input Port Names
- Initial Output Port Names
- GPI Trigger Source & Target List
- User Defined Remote Layer Initial Bank Settings
- Effects Parameters
- Effects and tempo synchronization
- Preset EQ Parameters
- Preset Gate Parameters (fs = 44.1kHz)
- Preset Compressor Parameters (fs = 44.1kHz)
- Dynamics Parameters
- Appendix B: Specifications
- Appendix C: MIDI
- Appendix D: Options
- Index
- DM2000 Block Diagram
- DM2000 Level Diagram
- MIDI Implementation Chart
384 Appendix C: MIDI
DM2000 Version 2—Owner’s Manual
13.4.27 Parameter change (Remote meter)
When transmission is enabled by receiving a Request of Remote meter, the
specified meter information is transmitted every 50 msec for 10 seconds.
When you want to transmit meter information continuously, a Request
must be transmitted continuously within every 10 seconds.
Reception
This is echoed if [Parameter change ECHO] is ON.
Transmission
When transmission has been enabled by a Request, the parameter specified
by Address will be transmitted on the [Rx CH] channel at 50 msec intervals
for a duration of 10 seconds.
Transmission will be disabled if the power is turned off and on again, or if
the PORT setting is changed.
If [Parameter change ECHO] is ON, this message will be retransmitted
without change.
13.4.28 Parameter request (Remote meter)
Reception
If [Parameter change RX] is ON and the [Rx CH] matches the Device
Number included in the SUB STATUS, these messages are received. If [Pa-
rameter change ECHO] is ON, these messages are echoed.
When this is received, data of the specified address is transmitted on the
[Rx CH] at intervals of 50 msec as a rule, for a period of 10 seconds.
If Address UL= 0x7F is received, transmission of all meter data will be halt-
ed immediately. (disable)
Transmission
If [Parameter change ECHO] is ON, this message will be retransmitted
without change.
13.4.29 Parameter change (Remote time counter)
When transmission is enabled by receiving a Request of Remote Time
Counter, the Time Counter data is transmitted every 50 msec for 10 sec-
onds. When you want to transmit Counter information continuously, a
Request must be transmitted within every 10 seconds.
Reception
This is echoed if [Parameter change ECHO] is ON.
Transmission
When transmission is enabled by receiving a Request, the Time Counter
information is transmitted on [RxCH] channel every 50 msec for 10 sec-
onds.
Transmission will be disabled if the power is turned off and on again, or if
the PORT setting is changed.
If [Parameter change ECHO] is ON, this message will be retransmitted
without change.
13.4.30 Parameter request (Remote time counter)
Reception
If [Parameter change RX] is ON and the [Rx CH] matches the Device
Number included in the SUB STATUS, these messages are received. If [Pa-
rameter change ECHO] is ON, these messages are echoed.
When this is received, the Time Counter information is transmitted on the
[Rx CH] channel every 50 msec for 10 seconds.
When the second byte of Address is received on 0x7F, data transmission
will be halted immediately. (disable)
Transmission
If [Parameter change ECHO] is ON, this message will be retransmitted
without change.
13.4.31 Parameter change (Automix status)
When transmission is enabled by receiving a Request of Automix status,
the Automix Status data is transmitted every second for 10 seconds. When
you want to transmit the Automix Status information continuously, the
Request must be transmitted continuously minimum within 10 seconds
interval. The data is transmitted continuously while the transmission is en-
abled, even when the Automix Status on the DM2000 has been changed.
Reception
This is echoed if [Parameter change ECHO] is ON.
Transmission
When the transmission is set to enable by receiving a Request. The Auto-
mix Status data is transmitted on the [Rx CH] channel every second for 10
seconds. The data is transmitted continuously while the transmission is
enabled, even when the Automix Status on the DM2000 has been changed.
Transmission will be disabled if the power is turned off and on again, or if
the PORT setting is changed.
If [Parameter change ECHO] is ON, this message will be retransmitted
without change.
STATUS 11110000 F0
System exclusive message
ID No. 01000011 43
Manufacture's ID number (YAMAHA)
SUB STATUS 0001nnnn 1n
n=0-15 (Device number=MIDI Channel)
GROUP ID 00111110 3E
MODEL ID (digital mixer)
MODEL ID 00000110 06
DM2000
ADDRESS 00100001 21
Remote meter
0mmmmmmm mm
ADDRESS UL
0mmmmmmm mm
ADDRESS LU
0mmmmmmm mm
ADDRESS LL
DATA 0ddddddd dd
data1 H
0ddddddd dd
Data1 L
:
:
EOX 11110111 F7
End of exclusive
STATUS 11110000 F0
System exclusive message
ID No. 01000011 43
Manufacture's ID number (YAMAHA)
SUB STATUS 0011nnnn 3n
n=0-15 (Device number=MIDI Channel)
GROUP ID 00111110 3E
MODEL ID (digital mixer)
MODEL ID 00000110 06
DM2000
ADDRESS 00100001 21
Remote meter
0mmmmmmm mm
ADDRESS UL
0mmmmmmm mm
ADDRESS LU
mmmmmmm mm
ADDRESS LL
0ccccccc ch
Count H
0ccccccc cl
Count L
EOX 11110111 F7
End of exclusive
STATUS 11110000 F0
System exclusive message
ID No. 01000011 43
Manufacture's ID number (YAMAHA)
SUB STATUS 0001nnnn 1n
n=0-15 (Device number=MIDI Channel)
GROUP ID 00111110 3E
MODEL ID (digital mixer)
MODEL ID 00000110 06
DM2000
ADDRESS 00100010 22
Remote Time counter
0000tttt 0t
0:Time code, 1:Measure.Beat.Clock
0ddddddd dd
Hour / Measure H
0ddddddd dd
Minute / Measure L
DATA 0ddddddd dd
Second / Beat
0ddddddd dd
Frame / Clock
EOX 11110111 F7
End of exclusive
STATUS 11110000 F0
System exclusive message
ID No. 01000011 43
Manufacture's ID number (YAMAHA)
SUB STATUS 0011nnnn 3n
n=0-15 (Device number=MIDI Channel)
GROUP ID 00111110 3E
MODEL ID (digital mixer)
MODEL ID 00000110 06
DM2000
ADDRESS 00100010 22
Remote Time counter
0ddddddd dd
0:Transmission request,
0x7F:Transmission stop request
EOX 11110111 F7
End of exclusive
STATUS 11110000 F0
System exclusive message
ID No. 01000011 43
Manufacture's ID number (YAMAHA)
SUB STATUS 0001nnnn 1n
n=0-15 (Device number=MIDI Channel)
GROUP ID 00111110 3E
MODEL ID (digital mixer)
MODEL ID 00000110 06
DM2000
ADDRESS 00100011 23
Automix status
00000000 00
0000dddd 0d
Automix status H
0000dddd 0d
Automix status L
EOX 11110111 F7
End of exclusive